Maxcess MAGPOWR GTS Load Cell User Manual

Maxcess MAGPOWR GTS Load Cell User Manual

Advertisement

Quick Links

MAGPOWR TENSION CONTROL
MAGPOWR GTS Load Cell
User Manual
EN
MI 850A347 1 A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MAGPOWR GTS Load Cell and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Maxcess MAGPOWR GTS Load Cell

  • Page 1 MAGPOWR TENSION CONTROL MAGPOWR GTS Load Cell User Manual MI 850A347 1 A...
  • Page 2: Table Of Contents

    Maintenance and repair ..................3-3 Decommissioning....................3-3 INSTALLATION Mechanical and electrical installation ..............4-1 Top plate adapters ....................4-3 Top plate adapter kits ..................4-3 Adapter kit installation ................4-4 SPECIFICATIONS SERVICE AND PARTS www.maxcessintl.com MAGPOWR GTS Load Cell MI 850A347 1 A...
  • Page 3: Introduction

    INTRODUCTION About these All of the information herein is the exclusive proprietary property of Maxcess International and is disclosed with the operating understanding that it will be retained in confidence and will instructions neither be duplicated nor copied in whole or in part nor be used for any purpose other than for which disclosed.
  • Page 4: Product Overview

    Size Models A, B Maximum force Pounds = English Kilograms = Metric Connector type EC12 Units type Blank = English units M = Metric units (dimensions and force) Specials: Other variations www.maxcessintl.com MAGPOWR GTS Load Cell MI 850A347 1 A...
  • Page 5: Available Models

    GTSB1100-EC12 1100 lbs GTSB2200-EC12 2200 lbs Metric series Force rating GTSA10-EC12M 10 kg GTSA25-EC12M 25 kg GTSA50-EC12M 50 kg GTSB100-EC12M 100 kg GTSB250-EC12M 250 kg GTSB500-EC12M 500 kg GTSB1000-EC12M 1000 kg www.maxcessintl.com MAGPOWR GTS Load Cell MI 850A347 1 A...
  • Page 6: Selection And Sizing

    0.9849 0.1736 direction away from the load cell, the signal 0.5736 0.8192 0.9962 0.0872 leads must be reversed at the terminal block of 0.6428 0.7660 1.0000 0.0000 the control. 0.7071 0.7071 www.maxcessintl.com MAGPOWR GTS Load Cell MI 850A347 1 A...
  • Page 7: Safety Instructions

    The signal word CAUTION refers to the danger of slight to moderate bodily injuries or material damage. The signal word NOTICE refers to the possibility of damage to equipment. www.maxcessintl.com MAGPOWR GTS Load Cell MI 850A347 1 A...
  • Page 8: Symbols Used

    WARNING/CAUTION – Danger due to voltage, electric shock Reference to danger of injury caused by electric shock due to voltage. WARNING/CAUTION – Danger due to hot surfaces Reference to risk of injury caused by burning. www.maxcessintl.com MAGPOWR GTS Load Cell MI 850A347 1 A...
  • Page 9: Proper Use

    Decommissioning The load cell must be disposed of in accordance with all the applicable national, state and local regulations. www.maxcessintl.com MAGPOWR GTS Load Cell MI 850A347 1 A...
  • Page 10: Installation

    NOTE: If the resultant force is “upward” (away from the load cell), reverse the black (-s) and white (+s) signal leads at the readout or control terminal Figure 2. Load Cell Wiring block. www.maxcessintl.com MAGPOWR GTS Load Cell MI 850A347 1 A...
  • Page 11 M10 X 1.75 15.9 12.7 GTSB INCHES 11.19 10.000 6.250 1.25 2.50 3.88 12.0 0.500 7/16-14 UNC 1.00 1.00 GTSBM 284.2 254.00 158.75 31.8 63.5 98.4 304.8 12.70 M12 X 1.75 25.4 25.4 www.maxcessintl.com MAGPOWR GTS Load Cell MI 850A347 1 A...
  • Page 12: Top Plate Adapters

    2 rails and four M6 screws 12 mm T-Slot Kit for GTSAM; includes 2 rails and four M6 screws Blank Top Plate Kit for GTSBM; includes plate and four M10 screws www.maxcessintl.com MAGPOWR GTS Load Cell MI 850A347 1 A...
  • Page 13: Adapter Kit Installation

    2. Position the TA3 adapter over the (4) mounting holes in the top of the GTSBM load cell 3. Install the (4) screws through the counter-bored holes in the adapter plate. www.maxcessintl.com MAGPOWR GTS Load Cell MI 850A347 1 A...
  • Page 14: Specifications

    GTSB250-EC12M = 0.23 mm [0.009 in.] Deflection at full load GTSB1100-EC12 = 0.15 mm [0.006 in.] GTSB500-EC12M = 0.15 mm [0.006 in.] GTSB2200-EC12= 0.38 mm [0.015 in.] GTSB1000-EC12M= 0.38 mm [0.015 in.] www.maxcessintl.com MAGPOWR GTS Load Cell MI 850A347 1 A...
  • Page 15 Part #LCC5M, or mating connector Part Cable Connector #12B220-1 (pin 1, +power; pin 2, + signal; pin 3, -signal; pin 4, -power) Climate Class 3K4 (EN60721) IP Protection IP67 (EN60529) Classification www.maxcessintl.com MAGPOWR GTS Load Cell MI 850A347 1 A...
  • Page 16 AND AFRICA AND SE ASIA Tel +1.405.755.1600 Tel +86.756.881.9398 Tel +91.22.27602633 Tel +81.43.421.1622 Tel +49.6195.7002.0 asia@maxcessintl.com Fax +1.405.755.8425 Fax +86.756.881.9393 Fax +91.22.27602634 Fax +81.43.421.2895 Fax +49.6195.7002.933 www.maxcess.asia sales@maxcessintl.com info@maxcessintl.com.cn india@maxcessintl.com japan@maxcessintl.com sales@maxcess.eu www.maxcessintl.com www.maxcessintl.com.cn www.maxcess.in www.maxcess.jp www.maxcess.eu © 2018 Maxcess...

Table of Contents