Chapter 7 Menu description tables

7-2-7 DOWNCON SETTING

Variable
Item
range
DOWNCON MODE
SQUEEZ
For setting the mode of the down converter
LT-BOX
output signals.
S-CROP
C U F R
DETAIL
ON
For setting the detail function for the down
OFF
converter output signals ON/OFF.
The down converter output signals contain
detailed components that are set during HD
signal processing. In this setting, these
signals overlap the detailed components
dedicated to the down converter outputs.
Even if this setting is turned off, it is
impossible
components
processing.
C U F R
H.DTL LEVEL
00
For setting the horizontal detail correction
:
level for the down converter output signals.
08
:
31
C U F R
V.DTL LEVEL
00
For setting the vertical detail correction level
:
for the down converter output signals.
04
:
31
C U F R
DTL CORING
00
For setting the noise elimination level of the
01
details.
:
15
C U F R
H.DTL FREQ.
1
For
:
frequencies.
3
1: 2.5 MHz
:
5
2: 3 MHz
3: 3.5 MHz
C U F R
2DLPF
ON
For setting the 2-D low path filter reducing
OFF
cross colors.
ON: Cross colors are reduced.
OFF: Cross colors are not reduced.
C U F R
SET UP
For setting the setup level for the down
For AJ-HDX900E
0%
converter output signals.
For AJ-HDX900P
7.5%
<Note>
When the system frequency is set to 50 Hz,
C U F R
the setup level will be 0%.
The underlining in the variable range column indicates the setting in the preset
mode.
Remarks
to
turn
off
the
detailed
set
during
HD
signal
selecting
the
horizontal
detail
4: 4 MHz
5: 4.5 MHz
(continued)

7-2-8 GENLOCK

Variable
Item
range
GENLOCK
INT
EXT
C U F R
GL PHASE
HD SDI
COMPOSIT
C U F R
H PHASE COARSE –100
:
+000
:
+100
H PHASE FINE
–100
:
+000
:
+100
Remarks
For setting the standard signals for
executing the GENLOCK.
INT: For synchronizing to the standard
signal within the unit regardless of the
signals that are input in the GENLOCK
IN connector.
EXT: For synchronizing to the standard
signals that are input in the GENLOCK
IN connector.
For selecting the output signals that lock
phases to the signals that are input in the
GENLOCK IN connector.
HD SDI:
For locking the HD SDI signals to the
GENLOCK input.
For the down converter output signals,
the start position of the video delays by
about 90 lines.
COMPOSIT:
For locking the down converter output
signals to the GENLOCK input.
For the HD SDI output signals, the start
position of the video gains by about 90
lines.
For making coarse adjustment for aligning
phases of the horizontal synchronization, for
executing the GENLOCK.
For making fine adjustment for aligning
phases of the horizontal synchronization, for
executing the GENLOCK.
7