IDE...F ErP • IND...F ErP
tor, the limiter protects the hot water tank from harmful overheating by turning
off the heating when the water temperature reaches 95 °C. The limiter MUST BE
RESET BY A PROFESSIONAL after resolving the cause of the overheating.
In case of appliances of type IDE...F and IDE...S, the controlling of electric heat-
ing and temperature is performed by a separate temperature controller. In case
of electric heating, it is not possible to control the temperature of the water to be
heated with the help of the button of the controller mounted onto the outside
cover.
8.5.
Electric immersion heater (for IDExxxF ErP types)
In case of failure, the replacement of the electric immersion heater requires dis-
connection from the electrical network and the discharge of water, as well as the
removal of the bolts in the service cover. THE REPAIR MUST BE PERFORMED BY A
PROFESSIONAL .
8.6.
Active anode
The hot water storage tank is additionally protected against corrosion by active
anodes. The service life of the active anodes is subject to the water quality and
the operating conditions. The condition of the anodes must be checked upon
each descaling operation, but at least once every two years. Its replacement re-
quires the disconnection of the power supply; such replacement requires the dis-
connection of the electrical circuit and the removal of the service cover. After re-
moving the service cover, it is recommended to perform reassembling using a
new sealing. The technician determines the time of the next inspection. If the di-
ameter of the anode decreases by 10mm anywhere, it must be replaced. After re-
placement of the anode, its earthing must be implemented according to the origi-
nal state. Adequate metal-through connection between the active anode and the
earthing bolt is essential.
8.7.
Defrosting
Taking the appliance out of service requires the removal of power, and the total
emptying of the container. When putting back into operation, refill the appliance
with water, before connecting to the electrical network.
8.8.
Summary of periodical inspections
Bimonthly:
check of safety valve
28
2
Biyearly:
Descaling
Active anode inspection
Radiator inspection
Check of hydraulic connections.
Check of the condition of electrical assemblies