ED900 (Fine Cover) Owner's Manual Table of Contents Table of contents Table of contents General information To our customers What you should know Distributor information ED900 low energy operator Low energy power operated swinging doors ANSI/BHMA A156.19 Mode switch and Exit Only switch panels...
NOTICE in personal injury or threat to health. Installation on an interior building surface. CAUTION The ED900 with fine cover must be installed on an interior building surface. This symbol warns of a potentially unsafe Interior door installation. procedure or situation.
ED900 (Fine Cover) Owner's Manual Chapter 2 2 To our customers 2.1 Service availability. We are pleased that a dormakaba ED900 low energy swing door system has been selected for this dormakaba USA, Inc. has a nationwide network of installation.
3.1 Distributor information 3.2 ED900 low energy operator 3.1.1 dormakaba USA Inc. distributor information. ED900 operator is available only as a low energy Be sure that the dormakaba USA Inc. distributor has operator (Para. 3.3). provided the following information for each door 3.3 Low energy power operated...
Low energy swing door safety information label. Fig. 4.1.1 Safety Information and Annual Compliance This AAADM label outlines safety checks that should be Inspection labels performed daily on swing door controlled by an ED900 low energy operator. ANNUAL COMPLIANCE SAFETY INFORMATION INSPECTION 4.1.2...
• Force to prevent the door from closing should not 5. Have door inspected by a dormakaba USA Inc. exceed 15 pounds measured with a force gauge. AAADM certified technician annually, at a minimum. 4. Door safety signage •...
ED900 (Fine Cover) Owner's Manual Chapter 6 6 ED900 door signage 6.1 Low energy operator 6.1.1 Overview Fig. 6.1.1 AUTOMATIC CAUTION DOOR decal Signage and warnings are specified in ANSI /BHMA A156.19, American National Standard for Power Assist AUTOMATIC and Low Energy Power Operated Doors.
ED900 (Fine Cover) Owner's Manual Chapter 6 6.2 Door signage, low energy single swing door, ANSI/BHMA A156.19 Fig. 6.2.1 Knowing act device initiation of door operation Fig. 6.2.2 Push / Pull initiation of door operation Push to Operate Pull to Operate...
Page 11
ED900 (Fine Cover) Owner's Manual Chapter 6 Fig. 6.3.4 Push / Pull, pull to operate Fig. 6.3.3 Push / Pull, push to operate AUTOMATIC AUTOMATIC CAUTION CAUTION AUTOMATIC AUTOMATIC CAUTION CAUTION DOOR DOOR DOOR DOOR DD0586-010 DD0586-010 DD0586-010 DD0586-010...
7.1 Environment 7.1.1 ED50LE/ED100LE environmental requirements. Table 7.1.1 Operator environmental requirements. The ED900 with fine cover is designed to operate on an Ambient temperature 50 to 122 °F [-150 to 500C] interior building surface under the specifications shown in Table 7.1.1.
Page 13
ED900 (Fine Cover) Owner's Manual Blank page This page left intentionally blank. ED900 08125360 09-2021...
Page 14
USA, Inc. 1 Dorma Drive, Drawer AC Reamstown, PA 17567 T: 717-336-3881 F: 717-336-2106 www.dormakaba.us...
Need help?
Do you have a question about the ED900 and is the answer not in the manual?
Questions and answers