Dormakaba ED900 Owner's Manual

Dormakaba ED900 Owner's Manual

Low energy swing door operator (fine cover)

Advertisement

Quick Links

ED900
Low Energy Swing Door Operator
(Fine cover)
Owner's Manual
08125360 – 02-2020
| EN |

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ED900 and is the answer not in the manual?

Questions and answers

Summary of Contents for Dormakaba ED900

  • Page 1 ED900 Low Energy Swing Door Operator (Fine cover) Owner's Manual 08125360 – 02-2020 | EN |...
  • Page 2: Table Of Contents

    ED900 (Fine Cover) Owner's Manual Table of Contents Table of contents Table of contents General information To our customers What you should know Distributor information Knowing act Program switches Optional key switch panels AAADM Safety information labels Safety information labels, low energy power...
  • Page 3: General Information

    ED900 (Fine Cover) Owner's Manual Chapter 1 1 General information 1.1 Owner's Manual 1.7 ANSI/BHMA A156.19, American National This Owner's Manual applies to the dormakaba Standard for Power Assist and Low Energy Power ED900 low energy swing door system.
  • Page 4: To Our Customers

    Chapter 2 and 3 2 To our customers 3 What you should know We are pleased that a dormakaba ED900 low energy swing door system has been selected for this installation. 1. dormakaba ED900 Owner's Manual content. dormakaba designed, tested and built the system to 2.
  • Page 5: Program Switches

    ED900 (Fine Cover) Owner's Manual Chapter 3 3.3 Program and Exit Only switches 3.3.1 Program switch control modes. • Auto, door opens following pulse • Open, door opens automatically and generation by a knowing act device or remains open.
  • Page 6: Aaadm Safety Information Labels

    Low energy swing door safety information label. Fig. 4.1.1 Safety Information and Annual Compliance This AAADM label outlines safety checks that should be Inspection labels performed daily on swing door controlled by an ED900 low energy operator. ANNUAL COMPLIANCE SAFETY INFORMATION INSPECTION 4.1.2...
  • Page 7: Daily Safety Check Procedures

    2. Check all doors for damage. be in good condition. 3. Force 5. Have door inspected by a dormakaba USA Inc. • Force to prevent the door from closing should not AAADM certified technician annually, at a minimum.
  • Page 8: Ed900 Door Signage

    ED900 (Fine Cover) Owner's Manual Chapter 6 6 ED900 door signage 6.1 Low energy operator 6.1.1 Overview Fig. 6.1.1 AUTOMATIC CAUTION DOOR decal Signage and warnings are specified in ANSI /BHMA A156.19, American National Standard for Power Assist AUTOMATIC and Low Energy Power Operated Doors.
  • Page 9: Door Signage, Low Energy Double Swing Doors

    ED900 (Fine Cover) Owner's Manual Chapter 6 6.3 Door signage, low energy double swing doors Fig. 6.3.4 Knowing act, non-hinge side Fig. 6.3.1 Knowing act, non-hinge side AUTOMATIC AUTOMATIC CAUTION CAUTION AUTOMATIC AUTOMATIC CAUTION CAUTION DOOR DOOR DOOR DOOR...
  • Page 10: Ed900 Cleaning

    7.1 ED900 environment and cleaning 7.1.1 ED900 environmental requirements. Table 7.1.1 Operator environmental requirements. ED900 with fine cover is designed to operate on an Ambient temperature 5 to 122 °F interior building application under the specifications shown in Table 7.1.1.
  • Page 11 ED900 (Fine Cover) Owner's Manual Blank page This page left intentionally blank. ED900 08125360 02-2020...
  • Page 12 USA, Inc. 1 Dorma Drive, Drawer AC Reamstown, PA 17567 T: 717-336-3881 www.dormakaba.com F: 717-336-2106...