Introduction; Control Specifications; General; Sdm-Cd16D - Campbell SDM-CD16D User Manual

16 channel digital control port expansion module
Hide thumbs Also See for SDM-CD16D:
Table of Contents

Advertisement

SDM-CD16D 16 Channel Digital Control
Port Expansion Module
The SDM-CD16D (see Figure 1) is a synchronously addressed peripheral. It has 16 control
ports and is compatible with Campbell Scientific's CR10/10X, CR23X, CR7 and 21X
dataloggers.

1. Introduction

NOTE

2. Control Specifications

2.1 General

Figure 1 SDM-CD16D
The SDM-CD16D expands the digital output capability of Campbell Scientific
dataloggers. The outputs can be set to 0 or 5V by the datalogger. In addition to
being able to drive normal logic level inputs, when an output is set HI a 'boost'
circuit allows it to source a current of up to 100mA, allowing direct control of low
voltage valves, relays etc.
The SDM-CD16D is a synchronously addressed datalogger peripheral. Datalogger
control ports 1, 2 and 3 are used to address the SDM-CD16D then clock out the
desired state of each of the 16 control ports. Up to sixteen SDM-CD16Ds may be
addressed, making it possible to control a maximum of 256 ports from the first
three datalogger control ports.
CR10/10X, CR23X, CR7 and 21X dataloggers use I/O Instruction
104 to control the SDM-CD16D.
Older dataloggers with pre-OS7.1 software may not have the
necessary instruction, or may use Instruction 29. Ensure that your
datalogger contains the appropriate instruction before using.
Compatible dataloggers:
Operating voltage:
Current drain at 12V DC: 100µA typical (All ports HI, no load)
Total cable length:
CR10/10X, CR23X, CR7 and 21X
12V DC nominal (9 to 18V)
6m (CR10/10X, CR23X, 21X), 180m (CR7)