1-8. Measures when ALARM Indicator Lights up
In the Case of 3
3
3
3
3
n
At that time, LED (D14) on the IF-715 board lights up.
(1) Check that the temperature in the operating condition is within the performance guarantee range.
(Refer to Section 1-3 of the installation manual for operating condition.)
(2) When the cause is found, turn off the power of this unit and hybrid recorder.
(3) Measure to recover from the error, then turn on the power again.
In the Case of 4
4
4
4
4
Take corrective action both 1 and 2.
5
5
In the Case of 5
5
5
Take corrective action both 1 and 3.
In the Case of 6
6
6
6
6
n
At that time, LED (D6) on the IF-715 board lights up.
(1) Turn off the power of this unit and hybrid recorder.
(2) Check the power supply line (power supply cable, POWER switch, supply power voltage, etc.).
(3) Measure to recover from the error, then turn on the power again.