Link In - Nuvation Energy High-Voltage BMS Installation Manual

Table of Contents

Advertisement

Pin
Connection
1
VBUS
2
COM
3
IPA
4
IMA

4.4.2. Link In

The Link In connector provides power and communication to this Cell Interface from the Cell Interface
modules below this Cell Interface, or from the Stack Controller if this Cell Interface is measuring the
most negative cell in the stack.
The amount of current sourced into this connector is the sum of current consumed by this Cell
Interface and all those above it (which amounts to all Cell Interface modules if this Cell Interface is
measuring Cell 1).
Connect to the Link Out connector on the Cell Interface that is measuring the previous series-
connected cell below this Cell Interface to this connector, or connect the Stack Controller to this
connector if this Cell Interface is measuring the bottom cell in the stack.
Document ID: NE-IG-001
Table 13. Link Out: Molex Micro-Fit 3.0 Connector
Molex 43025-0400
Manufacturer
Housing
Housing material
Circuits
Crimp terminal
Wire gauge range
Table 14. Link Out Connector Pin Assignment
Description
DC power from Stack Controller, with Fault
Pilot Signal
Power return from Stack Controller
Link Bus differential pair plus
Link Bus differential pair minus
Nuvation Energy High-Voltage BMS - Installation Guide
Molex Incorporated
43025-0400
Nylon UL94V-0
4
43030-0002
AWG20-24 stranded
15
Connected to Device
Cell Interface
Cell Interface
Cell Interface
Cell Interface
Rev 2.1, 2020-03-13

Advertisement

Table of Contents
loading

Table of Contents