Pin
Connection
1
VBUS
2
COM
3
IPA
4
IMA

4.4.3. Battery Cells

The Battery Cells connector provides cell voltage input and a means for balancing the cells. The cable
wire should be rated for at least 750mA to survive worse-case current.
Pins 8, 16, 17, and 18 are
12, 13, 14, 15, 16, and 17 are
All unused voltage inputs should be tied to the next highest potential voltage sense input. In this way,
all pins should be connected with the exception of pins 8, 16, 17 and 18 in the Cell Interface - 12
channel model and pins 2, 4, 6, 8, 10, 11, 12, 13, 14, 15, 16, and 17 in the Cell Interface - 12V 4
channel model.
Connect the battery cell voltage sense leads to this connector.
Table 17. Battery Cells: Molex Micro-Fit 3.0 Connector
Document ID: NE-IG-001
Table 15. Link In: Molex Micro-Fit 3.0 Connector
Molex 43025-0400
Manufacturer
Housing
Housing material
Circuits
Crimp terminal
Wire gauge range
Table 16. Link In Connector Pin Assignment
Description
DC power from Stack Controller, with Fault
Pilot Signal
Power return from Stack Controller
Link Bus differential pair plus
Link Bus differential pair minus
No Connect
in the Cell Interface - 12 channel model. Pins 2, 4, 6, 8, 10, 11,
No Connect
in the Cell Interface - 12V 4 channel model.
Nuvation Energy High-Voltage BMS - Installation Guide
Molex Incorporated
43025-0400
Nylon UL94V-0
4
43030-0002
AWG20-24 stranded
16
Connected to Device
Cell Interface
Cell Interface
Cell Interface
Cell Interface
Rev 2.1, 2020-03-13