Battery Cell Connecter for Cell Interface - 12 channel

Table 18. Cell Interface - 12 channel Battery Cell Connector Pin Assignment
Pin
Connection
1
CELL0
2
CELL2
3
CELL4
4
CELL6
5
CELL8
6
CELL10
7
CELL12
8
No Connect
9
No Connect
10
CELL1
11
CELL3
12
CELL5
13
CELL7
Document ID: NE-IG-001
Molex 43025-1800
Manufacturer
Housing
Housing material
Circuits
Crimp terminal
Wire gauge range
Description
Bottom reference of Cell Interface
Cell 2 voltage sense
Cell 4 voltage sense
Cell 6 voltage sense
Cell 8 voltage sense
Cell 10 voltage sense
Cell 12 voltage sense
Not Connected
Not Connected
Cell 1 voltage sense
Cell 3 voltage sense
Cell 5 voltage sense
Cell 7 voltage sense
Nuvation Energy High-Voltage BMS - Installation Guide
Molex Incorporated
43025-1800
Nylon UL94V-0
18
43030-0002
AWG20-24 stranded
17
Connected to Device
Connect to negative terminal of
the lowest cell (Cell 1)
Connect to positive terminal of
Cell 2
Connect to positive terminal of
Cell 4
Connect to positive terminal of
Cell 6
Connect to positive terminal of
Cell 8
Connect to positive terminal of
Cell 10
Connect to positive terminal of
Cell 12
No Connect
No Connect
Connect to positive terminal of
the lowest cell (Cell 1)
Connect to positive terminal of
Cell 3
Connect to positive terminal of
Cell 5
Connect to positive terminal of
Cell 7
Rev 2.1, 2020-03-13