Can 485 - Nuvation Energy High-Voltage BMS Installation Manual

Table of Contents

Advertisement

Pin
Connection
1
VBUS
2
COM
3
IPA
4
IMA

3.3.2. CAN 485

The CAN 485 connector contains both isolated CAN and non-isolated RS-485 (Modbus) connections.
Isolated CAN requires 5.5-12 Vdc sourced from an external power supply to operate. 120 Ω
termination for CAN is added by connecting pins 3 and 9 together. 150 Ω termination for Modbus is
added by connecting pins 6 and 12 together.
Keep the termination wire length short for best results. Connect external equipment to this connector.
Document ID: NE-IG-001
Table 2. Link Out: Molex Micro-Fit 3.0 Connector
Molex 43025-0400
Manufacturer
Housing
Housing material
Circuits
Crimp terminal
Wire gauge range
Table 3. Link Out Connector Pin Assignment
Description
DC power from Stack Controller, with Fault
Pilot Signal
Power return from Stack Controller
Link Bus differential pair plus
Link Bus differential pair minus
Nuvation Energy High-Voltage BMS - Installation Guide
Molex Incorporated
43025-0400
Nylon UL94V-0
4
43030-0002
AWG20-24 stranded
Connected to Device
Cell Interface
Cell Interface
Cell Interface
Cell Interface
6
Rev 2.1, 2020-03-13

Advertisement

Table of Contents
loading

Table of Contents