Harmonic Declaration; Wiring Figure - Beko BGMPI 090 User Manual

Table of Contents

Advertisement

Available languages

Available languages

5 Installation
C
In North America, please choose
the right cable size according to
the minimum circuit ampacity
indicated on the nameplate of
the unit.
– Using wire strippers, strip the rubber jacket
from both ends of the signal cable to reveal
approximately 15cm (5.9") of wire.
– Strip the insulation from the ends.
– Using a wire crimper, crimp u-lugs on the
ends.
C
When connecting the wires,
strictly follow the wiring diagram
found inside the electrical box
cover.
2. Remove the electric cover of the outdoor unit.
If there is no cover on the outdoor unit, take
off the bolts from the maintenance board and
remove the protection board.
3. Connect the u-lugs to the terminals Match the
wire colors/labels with the labels on the terminal
block, and firmly screw the u-lug of each wire to
its corresponding terminal.
4. Clamp down the cable with designated cable
clamp.
5. Insulate unused wires with electrical tape. Keep
them away from any electrical or metal parts.
6. Reinstall the cover of the electric control box.
36 / 124 EN
5�8 Harmonic declaration
"The equipment M4OB-36HFN8-Q complies with
IEC 61000-3-12 provided that the shortcircuit
power Ssc is greater than or equal to 4787737.5
at the interface point between the user's supply
and the public system. It is the responsibility of
the installer or user of the equipment to ensure, by
consultation with the distribution network operator
if necessary, that the equipment is con-nected only
to a supply with a short-circuit power Ssc greater
than or equal to 4787737.5." "The equipment
M5OD-42HFN8-Q complies with IEC 61000-3-12
provided that the shortcircuit power Ssc is greater
than or equal to 3190042.5 at the interface point
between the user's supply and the public system.
It is the responsibility of the installer or user of
the equipment to ensure, by consultation with the
distribution network operator if necessary, that the
equipment is con-nected only to a supply with a
short-circuit power Ssc greater than or equal to
3190042.5."
5�9 Wiring Figure
Cover
Cover
Screw
Screw
Multi Split Type Air Conditioner / User Manual
CAUTION!
connective
terminals, as identified, with
their matching numbers on the
terminal block of the indoor
and outdoor units. For example,
A
Terminal L1(A) of the outdoor unit
must connect with terminal L1/1
on the indoor unit. The outdoor
unit can match di erent types of
indoor unit, the numbers on the
terminal block of the indoor unit
may be slightly different. Please
pay special attention while
connecting the wire.
Connect
the
cables
to
the

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Bgmpi 120Bgmpo 181Bgmpo 211Bgmpo 271

Table of Contents