    Content Operation Notices Precautions......................1 Parts name ......................2 Screen Operation Guide Buttons on remote controller .................3 Introduction for icons on display screen ..............3 Introduction for buttons on remote controller............4 Function introduction for combination buttons............8 Operation guide .....................9 Replacement of batteries in remote controller............9 Emergency operation ..................10 Maintenance Clean and maintenance..................10...
  • Page 4: Precautions

    Precautions Warning cause electric shock. may be broken. damage. Please contact dealer when you need to repair air conditioner. person can perform the work. Otherwise, it may cause personal injury or damage. damage or personal injury. personal injury or damage. electric shock.
  • Page 5: Parts Name

    Parts name Indoor Unit air inlet panel aux.button air outlet cooling power receiver indicator indicator window display heating temp. drying indicator indicator indicator (Display content or position may be different from above remote control graphics, please refer to actual products) Outdoor Unit air inlet Connection wire...
  • Page 6: Buttons On Remote Controller

    Buttons on remote controller ON/OFF button MODE button button CLOCK button TIMER ON/TIMER OFF button TEMP button TURBO button LIGHT button SLEEP button Introduction for icons on display screen Set fan speed Send signal Operation mode Cool mode Set temperature Dry mode Fan mode Turbo mode...
  • Page 7: Introduction For Buttons On Remote Controller

    Introduction for buttons on remote controller Note: conditioner by using remote controller. ON/OFF button The colour is different for different models), and indoor unit will give out a sound. MODE button Press this button to select your required operation mode. COOL fan blowing angle.
  • Page 8 Introduction for buttons on remote controller auto mode) adjust time. (Refer to CLOCK, TIMER ON, TIMER OFF buttons) When setting to CLOCK, TIMER ON, TIMER OFF buttons) ), high( Auto Note: button Press this button can select up&down swing angle. Fan blow angle can be selected circularly as below: no display at current position)
  • Page 9 Introduction for buttons on remote controller CLOCK button Press this button to set clock time. " " icon on remote controller will blink. Press change quickly. Release this button when reaching your required time. Press Note: ller will quit setting status. Operation for TIMER ON/TIMER OFF is the same. TIMER ON / TIMER OFF button time will change quickly until reaching your required time.
  • Page 10 Introduction for buttons on remote controller function, and " "icon will disappear. Note: operate at low speed for a while to blow the residual water inside the air duct. will stop operation immediately. TEMP button remote controlleris selected circularly as below: no display on indoor unit displays set temperature.
  • Page 11: Function Introduction For Combination Buttons

    Introduction for buttons on remote controller SLEEP button " " icon is displayed on remote controller. Press this button again to cancel sleep function and " " icon will disappear. LIGHT button Press this button to turn off display light on indoor unit. " "...
  • Page 12: Operation Guide

    Operation guide turn on the air conditioner. adjusted under auto mode). speed. Press " " button to select fan blowing angle. Replacement of batteries in remote controller signal sender battery 1. Press the back side of remote controller marked the cover of battery box along the arrow direction. reinstall remove are correct.
  • Page 13: Emergency Operation

    Emergency operation If remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: air conditioner. When the air conditioner is turned on, it will operate under auto mode.
  • Page 14 Clean and maintenance Open panel Pull out the panel to a certain the water (below 45 ) to clean it, and then put it in a shady and cool place to dry. panel cover tightly. Note: operation environment, clean frequency can be increased.
  • Page 15 Clean and maintenance Checking before use-season 1. Check whether air inlets and air outlets are blocked. 2. Check whether circuit break, plug and socket are in good condition. 4. Check whether mounting bracket for outdoor unit is damaged or corroded. If yes, please contact dealer.
  • Page 16: Malfunction Analysis

    Malfunction analysis General phenomenon analysis Please check below items before asking for maintenance. If the malfunction still Phenomenon Check items Solution (such as static electricity,stable the plug after about 3min, and voltage)? then turn on the unit again. within the signal receiving range? Indoor unit Select proper angle and point...
  • Page 17 Malfunction analysis Phenomenon Check items Solution fuse is burnt out? circuit break or fuse. operate after stopping operation? on the unit again. for remote controller is correct? Mist is em- itted from temperature and humidity will idity is high? be decrease and mist will air outlet disappear.
  • Page 18 Malfunction analysis Phenomenon Check items Solution Odours are such as furniture and cigarette, emitted etc. ner operates such as thunder, wireless power, and then turn on the abnormally devices, etc. unit again. Outdoor ating mode, it may generate unit has vapor, which is a normal vapor phenomenon.
  • Page 19 Malfunction analysis Error Code ation of error code. Indoor for reference. Please refer to display actual product for the actual indicator and position. Error code Error code Troubleshooting It can be eliminated after restarting the unit. If not,please It can be eliminated after restarting the unit. If not,please It can be eliminated after restarting the unit.
  • Page 20: Installation Dimension Diagram

    Installation dimension diagram Space to the wall Space to the wall Drainage pipe...
  • Page 21: Tools For Installation

    Tools for installation 1 Level meter 2 Screw driver 3 Impact drill 4 Drill head 5 Pipe expander 6 Torque wrench 7 Open-end wrench 8 Pipe cutter 9 Leakage detector 10 Vacuum pump 11 Pressure meter 13 Inner hexagon spanner 14 Measuring tape Note: Selection of installation location...
  • Page 22: Requirements For Electric Connection

    Requirements for electric connection Safety precaution 1. Must follow the electric safety regulations when installing the unit. circuit break. 3. Make sure the power supply matches with the requirement of air conditioner. power supply cables before using the air conditioner. 4.
  • Page 23: Installation Of Indoor Unit

    Installation of indoor unit Step one: choosing installation location Step two: install wall-mounting frame plastic expansion particles in the holes. Step three: open piping hole 1. Choose the position of piping hole according to the direction of outlet pipe. The position of piping hole should be a little lower than the wall-mounted frame, shown as below.
  • Page 24 Installation of indoor unit Indoor outdoor Note: 5-10° Step four: outlet pipe 1. The pipe can be led out in the 2. When select leading out the pipe direction of right, rear right, left or from left or right, please cut off the rear left.
  • Page 25 Installation of indoor unit Hex nut diameter Tightening torque (N . m) open-end wrench 15~20 30~40 union nut 40~55 pipe torque wrench 60~65 70~75 indoor pipe 4. Wrap the indoor pipe and joint of con- nection pipe with insulating pipe, and then wrap it with tape.
  • Page 26 Installation of indoor unit 2. Make the power connection wire go cable-cross through the cable-cross hole at the back hole of indoor unit and then pull it out from the front side. power connection wire 3. Remove the wire clip; connect the power connection wire to the wiring terminal with wire clip.
  • Page 27 Installation of indoor unit Step eight: bind up pipe 1. Bind up the connection pipe, power drain hose connection pipe band cord and drain hose with the band. indoor and outdoor power cord indoor unit pipe indoor power cord liquid pipe 3.
  • Page 28: Installation Of Outdoor Unit

    Installation of outdoor unit (select it according to the actual installation situation) 1. Select installation location according to the house structure. 2. Fix the support of outdoor unit on the selected location with expansion screws. Note: installing the outdoor unit. Make sure the support can withstand at least four times of the unit weight.
  • Page 29 Installation of outdoor unit Step four: connect indoor and outdoor pipes 1. Remove the screw on the right han- 3. Pretightening the union nut with dle of outdoor unit and then remove hand. the handle. pipe joint screw union nut handle 2.
  • Page 30 Installation of outdoor unit 2. Fix the power connection wire and signal control wire with wire clip (only for cooling and heating unit). Note: Step six: neaten the pipes 1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Min. semidiameter of bending the pipe is 10cm.
  • Page 31: Vacuum Pumping

    Vacuum pumping Use vacuum pump 1. Remove the valve caps on the liquid valve and gas liquid valve piezometer valve and the nut of refri- gas valve gerant charging vent. refrigerant valve cap 2. Connect the charging hose charging vent nut of refrigerant gerant charging vent of gas charging vent...
  • Page 32: Check After Installation

    Check after installation Items to be checked Possible malfunction The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? (heating) capacity. It may cause condensation and water dripping. It may cause condensation and water Is water drained well? dripping.
  • Page 33 1. Standard length of connection pipe 2.Min. length of connection pipe is 3m. 3.Max. length of connection pipe and max. high difference. Max length Max length Cooling Max height Cooling Max height of connec- of connec- capacity difference capacity difference tion pipe tion pipe 5000Btu/h...
  • Page 34 Diameter of connection pipe Outdoor unit throttle Liquid pipe(mm) Gas pipe(mm) Cooling only(g/m) Cooling and heating(g/m)
  • Page 35: Pipe Expanding Method

    Pipe expanding method Note: Improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: E: Expand the port the distance of indoor unit and hard outdoor unit. mold expander pipe pipe pipe cutter Note: leaning...
  • Page 36 66129914641...

Table of Contents