Installation
6.4

Setting up devices

CAUTION
Danger of injury due to carrying of heavy loads
As the devices are very heavy, overloading poses a danger of injury while lifting and carrying them.
► Always have the devices lifted and carried by more than one person and plan a sufficient
► For very high loads, use a suitable hoist.

6.4.1 Indoor units

6
All in One units
Carry out the following steps to install the All in One unit:
Hydrokits
Carry out the following steps to install the hydrokit:
152
1
2
3
4
6
5
b
number of persons for the installation.
1. Carefully unpack the All in One unit at the installation location.
2. Align the device by means of the adjustable feet (use spirit level).
1. Exercise caution as you unpack the hydrokit at the installation site.
2. Attach the two mounting plates contained in the scope of delivery on the wall as shown in the
illustration (below). For this, use six M8 hexagon screws, washers and dowels with threaded
insert (all to be provided on site). Ensure horizontal alignment (use spirit level). Maintain the
minimum distances from the wall and floor specified in the corresponding illustration.
3. Have the hydrokit lifted by two persons and suspend the hydrokit by the slots on its rear
side, engaging them in the hooks of the top mounting plate. Ensure that the hooks engage
properly by moving them left and right.
4. In addition, attach the hydrokit by using three Phillips head screws on the bottom mounting
plate.
1 Inside
2 Wall
3 Outside
4 Sealing compound
a
5 Sleeve for cable grommet
6 Line bushing ø 70 mm
4
a approx. 5 – 7 mm
b 15 mm
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022