Planning
Mono-bloc systems
Models
WH-MDC05J3E5
L N
WH-MDC07J3E5
WH-MDC09J3E5
L N
WH-MDC12H6E5
WH-MDC16H6E5
WH-MXC09J3E5
WH-MXC12J6E5
WH-MXC09H3E5
WH-MXC12H6E5
WH-MHF09G3E5
WH-MHF12G6E5
5
Models
WH-MXC09J3E8
WH-MXC09H3E8
124
Power supply 1
Phases
Max. current
Max. power
consumption
consumption
(A)
(kW)
1
12.0
2.59
L N
L
N
L
N
1
1
1
1
17.0
3.71
1
17.0
3.83
L N
L
N
L
N
1
24.0
5.30
1
1
1
1
26.0
5.74
1
29.0
6.27
1
29.0
6.27
1
29.0
6.27
1
29.0
6.27
1
28.5
6.09
1
29.0
6.20
RCCB
Power supplies
Power supply 1
Phases
Max. current
Max. power
consumption
consumption
(A)
(kW)
3
14.7
9.99
3
14.7
9.96
RCCB
Power supplies
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Min. cable size
Phases
(mm²)
3 x 1.5
1
1
3 x 2.5
1
3 x 2.5
1
3 x 4.0
1
1
3 x 4.0
1
3 x 4.0
1
3 x 4.0
1
3 x 4.0
1
3 x 4.0
1
3 x 4.0 or
1
3 x 6.0
3 x 4.0 or
1
3 x 6.0
RCCB and power supplies
L
A1
1
Terminals on mono-bloc device
L N
L
N
1
1
2
Terminals on disconnector of the power supply
L N
L
N
1
1
L
Power supply 1 Power supply 2
A1
Min. cable size
Phases
(mm²)
5 x 1.5
1
5 x 1.5
1
RCCB and power supplies
1
L
L
L
N
L
N
A1
A2
A3
2
L
L
L
N
L
N
A1
A2
A3
Power supply 1
Power supply 2
Power supply 2
Max. current
Max. power
consumption
consumption
(A)
(kW)
13.0
3.0
13.0
3.0
13.0
3.0
26.0
6.0
26.0
6.0
13.0
3.0
26.0
6.0
13.0
3.0
26.0
6.0
13.0
3.0
26.0
6.0
N
N
L
L
L
L
L
A2
A1
A3
A2
A3
L
L
L
L
N
L
N
A2
A1
A3
A2
A3
Power supply 2
Max. current
Max. power
consumption
consumption
(A)
(kW)
13.0
3.0
13.0
3.0
Terminals on mono-bloc unit
Terminals on disconnector of the power supply
Min. cable size
(mm²)
3 x 1.5
3 x 1.5
3 x 1.5
3 x 4.0
3 x 4.0
3 x 4.0
3 x 4.0
3 x 4.0
3 x 4.0
3 x 4.0
3 x 4.0
L
N
L
N
L
N
L
N
Min. cable size
(mm²)
3 x 1.5
3 x 2.5