Panasonic Aquarea WH-ADC0309J3E5 Planning And Installation Manual page 121

Air-to-water heat pumps
Hide thumbs Also See for Aquarea WH-ADC0309J3E5:
Table of Contents

Advertisement

POWER SUPPLY 2
For model WH-SHF09F3E8
For model WH-SHF09F3E8
L B1
L B2
L B3
N
L
A1
LN
11
L
A1
For model WH-SHF12F9E8
For model WH-SHF12F9E8
Models
L
B1
L
B1
WH-SDC12H9E8 +
WH-UD12HE8
WH-SDC16H9E8 +
WH-UD16HE8
WH-SXC12H9E8 +
WH-UX12HE8
WH-SXC16H9E8 +
WH-UX16HE8
WH-SQC12H9E8 +
WH-UQ12HE8
WH-SQC16H9E8 +
WH-UQ16HE8
WH-SHF12F9E8 +
WH-UH12FE8
LN
For model WH-SHF09F3E8
For model WH-SHF12F9E8
Connection conditions
For hydrokits of the J and H generation:
● For the connection to the power supply, an approved polychloroprene-sheathed
● As connecting cable between indoor and outdoor units, an approved polychloroprene-
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
RCCB and power supplies
For model WH-SHF09F3E8
RCCB
POWER SUPPLY 2
POWER SUPPLY 1
POWER SUPPLY 1
For model WH-SHF12F9E8
L B1
L B2
L A1
L B3
L A2
N
L A3
N
L A1
L A2
L A3
N
1
2
3
4
5
Power supplies
L
L
N
1
L
2
L
3
L
4
N
5
A2
A3
N
L
N
L
A1
A2
A3
LN
11
N
L
L
L
L
L
N
A2
A3
A1
A2
A3
Power supply 1
Power supply 1
Phases
Max. current
Max. power
L
L
N
L
L
L
N
L
L
L
N
B2
B3
A1
B1
A2
B2
A3
B3
consumption
consumption
L
L
N
L
(A)
L
L
N
L
L
L
N
B2
B3
A1
A2
A3
B1
B2
B3
3
8.8
3
9.9
A
3
11.9
3
15.5
3
11.9
3
15.5
POWER SUPPLY 2
POWER SUPPLY 1
POWER SUPPLY 2
POWER SUPPLY 1
L B1
L B2
L B3
N
L A1
L A2
L A3
N
3
10.8
L B1
L B2
L B3
N
L A1
L A2
L A3
N
N
L
11
22
N
L
N
L
LN
11
45
RCCB and power supplies
For model WH-SHF09F3E8
L
L
L
N
A1
A2
A3
RCCB
L
L
L
N
POWER SUPPLY 2
A1
A2
A3
For model WH-SHF12F9E8
L B1
L B2
L B3
N
Power supplies
LN
11
L
L
L
N
B1
B2
B3
L
L
L
N
B1
B2
B3
Power supply 2
power cord, type designation 60245 IEC 57 or heavier cord, is to be used for mains
connection 1 and mains connection 2.
sheathed flexible cord, type designation 60245 IEC 57 or heavier cord, is to be used.
POWER SUPPLY 2
POWER SUPPLY 1
L B1
L B2
L B3
N
L A1
L A2
L A3
N
LN
11
N
L
45
POWER SUPPLY 2
L B1
L B2
L B3
L
L
L
N
A1
A2
A3
L
L
L
N
A1
A2
A3
LN
11
1
2
3
4
5
2
1
L
2
N
3
4
5
L
N
N
L
N
L
22
22
L
L
L
N
B1
B2
B3
3
L
N
L
N
L
L
L
N
B1
B2
B3
Power supply 2
1
2
3
4
5
1
2
Min. cable size
Phases
1
2
3
4
5
L
L
L
N
1
2
A1
A2
A3
(mm²)
(kW)
L
L
L
N
A1
A2
A3
5.85
5 x 1.5
3
6.59
5 x 1.5
3
A
7.91
5 x 1.5
3
POWER SUPPLY 2
POWER SUPPLY 1
L B1
L B2
L B3
N
L A1
L A2
L A3
N
LN
N
L
11
10.27
5 x 1.5
3
7.91
5 x 1.5
3
10.27
5 x 1.5
3
7.07
5 x 1.5
3
22
N
L
POWER SUPPLY 2
45
1
2
3
4
5
1
2
3
4
5
L
N
L B1
L B2
L B3
L
L
L
N
A1
A2
A3
L
N
POWER SUPPLY 1
L
L
L
N
A1
A2
A3
LN
11
L A1
L A2
L A3
N
1
2
3
4
N
L
2
1
2
3
4
L
L
L
N
A1
A2
A3
L
L
L
N
B1
B2
B3
3
L
L
L
N
A1
A2
A3
L
L
L
N
B1
B2
B3
Power supply 1
A
POWER SUPPLY 2
POWER SUPPLY 1
N
L
22
L B1
L B2
L B3
N
L A1
L A2
L A3
N
LN
N
L
11
POWER SUPPLY 1
Indoor unit /outdoor unit connection
1
Terminals on outdoor unit
1
2
3
4
5
2
Terminals on indoor unit
N
L A1
L A2
L A3
N
1
2
3
4
5
L
N
3
Terminals on disconnector of the power supply
L
N
N
L
Terminal block
Indoor unit / outdoor unit
1
2
A
1
2
3
L
L
L
N
1
2
3
A1
A2
A3
L
L
L
N
Connection of indoor unit
A1
A2
A3
and outdoor unit
Power supply 2
3
4
5
A
Max. current
Max. power
3
4
5
consumption
consumption
(A)
(kW)
13.0
9.0
13.0
9.0
13.0
9.0
N
L
22
13.0
9.0
45
13.0
9.0
13.0
9.0
13.0
9.0
POWER SUPPLY 1
Indoor unit / outdoor unit connection
1
Terminals on outdoor unit
1
2
3
4
5
2
Terminals on indoor unit
N
L A1
L A2
L A3
N
1
2
3
4
5
L
N
3
Terminals on disconnector of the power supply
L
N
N
L
Terminal block
Indoor unit / outdoor unit
1
2
5
1
2
3
N
L
22
5
L
L
L
N
1
2
3
A1
A2
A3
L
L
L
N
Connection of indoor unit
A1
A2
A3
and outdoor unit
A
N
L
22
45
Planning
N
L
22
3
4
5
1
4
5
2
4
5
Min. cable size
(mm²)
5 x 1.5
5 x 1.5
5 x 1.5
5 x 1.5
5
5 x 1.5
5 x 1.5
5 x 1.5
N
L
22
3
4
5
1
4
5
2
4
5
121

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents