Determination Of The Pipe Length Correction Factor For Bi-Bloc Systems; Example: Calculation Of The Total Heating Capacity Required - Panasonic Aquarea WH-ADC0309J3E5 Planning And Installation Manual

Air-to-water heat pumps
Hide thumbs Also See for Aquarea WH-ADC0309J3E5:
Table of Contents

Advertisement

Bivalent parallel operating mode (mono-energetic) via the heat pump's internal electric
backup heater
!
IMPORTANT
The bivalence point is defined individually for each building (→
heating capacity required, p.
efficiently even below their nominal capacity, without cycling.
5.1.5 Determination of the pipe length correction factor for bi-bloc
systems
The performance of bi-bloc systems with hydrokit or All in One indoor unit falls in proportion to the
increase in length of the refrigerant pipe. Depending on the nominal capacity of the heat pump, the
decrease of performance differs for the models with up to 7 kW nominal capacity and the models
with more than 7 kW nominal capacity (see the tables below).
Pipe length correction factors for bi-bloc systems up to 7 kW nominal capacity
Length of refrigerant pipe (one way)
Pipe length correction factor
Pipe length correction factors for bi-bloc systems above 9 kW nominal capacity
Length of refrigerant pipe (one way)
Pipe length correction factor

5.1.6 Example: Calculation of the total heating capacity required

The main requirements for the air-to-water heat pump are defined through the design heat load
and the design outside temperature. Moreover, the domestic hot water demand and electricity
shutdown times imposed by the electric utility company must be taken into account. Also, the
length of the connection pipes between outdoor unit and indoor unit (hydrokit or All in One unit) or
between mono-bloc unit and the building are to be considered, because long pipes lead to a lower
heating capacity. And not the least, besides the heat pump power, the supply water temperature at
design outside temperature is also decisive for selecting the right heat pump.
On the other hand, Aquarea heat pumps have an internal electric backup heater, which can provide
additional heating capacity while outside temperatures are very low.
Aquarea air-to-water heat pumps - Planning and installation manual - 02/2022
Maximum heat load
100 %
-15
-10
-5
95). Due to the inverter technology, Aquarea heat pumps can work
up to 10 m
up to 7 m
1.0
Bivalence point
0
5
10
Outside temperature (°C)
5.1.6 Calculation example: total
up to 20 m
1.0
0.95
up to 10 m
0.95
Planning
15
20
up to 30 m
0.90
up to 20 m
up to 30 m
0.90
0.85
95