L2 Repair Document
Storage relative humidity
Note*1: The capacity recovery rate should be more than 80% under the shipment status.
3.3.2. Charger test
When the standard charger is connected to the cell phone, check correct running of the
charge indicator on the display (refer to item 3.3.1 ).
Use the ampere meter to test the current of the charger.
2) Connect the power supply to ampere meter with adapter.
 Power on adapter
3) Connect the cables from "OUT" on other side to handset.
 Power on charger
4) Connect charger to the meter " IN " on the side
5) You can read the current on ampere-meter
6) The reading of the charger output should be 350 mA~550 mA

4. Software download

It is authorized to download software for the handset which needs to be updated. This
downloading tool is called "Sugar MTK_SP". Handset Software can be downloaded from
TS website via it. Thus internet access is necessary.
https://css.tclmobile.cn/.
Rev.
1.0
All rights reserved. Transfer, copy, use or communication of this file is prohibited without authorization.
65±20%
5010X/D/G/E/S/U Level 2 Repair Document
TCL
Communication Ltd.
TS Website:
Page
15/52