Calibration
It is important to ensure that all measurement devices are calibrated
regularly in order to maintain accuracy. A calibration program,
CALB832.EXE, is provided on the PCL-832 software disk to assist
with the calibration procedure.
The minimum equipment required to perform a satisfactory calibra-
tion is a 4½-digit digital multimeter.
Calibration is easily performed using the CALB832.EXE program.
This program is very user-friendly and will guide you through the
calibration and set-up procedure. A variety of prompts and graphic
displays will direct you to make the appropriate adjustments.
You should use this section in conjunction with the CALB832.EXE
program, as it does not contain precise calibration instructions.

VR Assignments

The PCL-832 has 12 on-board VRs (variable resistors). They enable
you to make accurate calibration adjustments for each axis's DA
offset, F/V offset and full-scale output. The location of each VR is
indicated in the figure on the next page. The function of each VR is
listed below:
VR1
VR2
VR3
VR4
VR5
VR6
VR7
VR8
VR9
VR10
VR11
VR12
58
PCL 832 User's Manual
:
CH1 DA output full scale adjustment
:
CH1 DA output offset adjustment
:
CH1 F/V output full scale adjustment
:
CH1 F/V output offset adjustment
:
CH2 DA output full scale adjustment
:
CH2 DA output offset adjustment
:
CH2 F/V output full scale adjustment
:
CH2 F/V output offset adjustment
:
CH3 DA output full scale adjustment
:
CH3 DA output offset adjustment
:
CH3 F/V output full scale adjustment
:
CH3 F/V output offset adjustment