(BURNING)
Adjustment of water Controls the water pump.
FIREDOWN
(EXTINGUIS
HING)

5.4. Warnings and alarms

Breakdowns and warnings about them are indicated by an audible signal and an alarm
message is displayed on the control panel in different background colour:
In cases of warning, the screen shows a message with the description of the signals,
for instance:
Low battery, call service for its
To close the warning screen, touch it. Closure of the warnings screen does not reset
the warning. After the warning screen is closed, the warning code is still present in the top
left corner of the main screen, as well as on all screens in standby mode:
52
Operation
Adjustment of air
Putting down
Cooling down
Low battery
replacement.
Automatic modulation from 1 through 5
according to the pre-set level of fuel power.
Controls the flue gas fan according to the air
required.
Stops feeding of pellets and air-purges the
firepot until the fire self-extinguishes.
Ensures water circulation until the appliance is
cooled down.
Error, probable causes:
1. Ignition failed,
2. Water overtemperature,
3. Backfire protection
Fire error