5.3.9. Manual feeding of the auger

Before switching on your heating device for the first time (or in case the fuel was run
out), the delivery auger may be completely empty and for this reason, the first ignition
may not be successful. To avoid this undesirable situation, it is necessary to enable the
function before starting up the heating device.
Enter "Settings"
After holding down the icon for 30 seconds, the manual feeding will be disabled again
automatically. If 30 seconds were not enough to fill up the delivery auger, hold down the
icon again. Repeat, until the pellets begin continuously falling in the firepot.
IMPORTANT! Please, make sure that you have emptied the firepot,
before starting up the heating device after performing the manual
feeding. Manual feeding during the operation of the heating device may
not be enabled!

5.3.10. Locking the keyboard

This option allows you to lock the screen, in order to prevent any inadvertent changes
of the settings. With enabled locking of the screen you can move around within the menu,
and show the current values, but you cannot edit any the settings, except for the screen
locking, itself.
-"OFF"-screen locking is disabled, all functions are available
-"LOW"-impossible change of the settings, only switching on/off of the heating
device is possible. When this option has been selected, the icon
row of the display.
-"HI"- all functions are locked (including the Switching on/off of the heating
device), only the option for returning to "LOW" or "OFF" is enabled). When this option has
been selected, the icon
When the function for locking of the screen has been pre-set to "LOW" or "HI", all
disabled options are light-grey.
IMPORTANT! Using the option for locking of the screen is recommend,
in cases when children without parental supervision have access to the
keyboard, or when cleaning the control panel.

5.3.11. Setting up temperature modes:

The controller allows the simultaneous option for adjustment of the temperature of
the water between 50°С ÷ 80°С or the temperature of the ambient air between 2°С ÷ 51°С,
and priority of action shall have the temperature, which achieves the pre-set point first.
→ "Manual feeding" → "Dose"
appears in the top row of the display.
appears in the top