the working condition of this chimney is good and the flue gases from the stove cannot
find their way from the chimney into any residential or other rooms.
It is recommended to avoid any horizontal flue sections, and where this is not possible,
their length must be less than 3 m and their incline - greater than 5%.
Periodicity of cleaning of carbon deposit and condensation of the flue pipes depends
on the conditions on site and the place of installation, and must be agreed upon at the
moment of commissioning with the servicing chimney sweeper.

4.3. Fresh air intake for the combustion process

To ensure normal combustion process and clean surrounding atmosphere sufficient
amount of air must be supplied. If the room has tightly fitted doors and windows, it is
necessary to provide for external air inflow in the area behind the appliance, such as
ventilation pipe in the wall with a grate, turned to the outside. Direct connection of the
stove to an external air intake pipe is not recommended.
Presence of any system that sucks out air is not recommended in the room where the
appliance is installed, and where one exists, forced delivery air-compensation device is
required.

4.4. Connection to the Water Heating System (WHS)

IMPORTANT! Connection of the stove to the WHS must only be done
by a licensed installer and in compliance with the operating legal
provisions!