Contact Operation - IDEC HS1C Series Instruction Sheet

Solenoid type safety switch

Advertisement

INSTRUCTION SHEET - HS1C Series
5

Contact Operation

Contact Configuration
Type
Indicator
(
+
)
7
Main Circuit :
HS1C-R44R-
Monitor Circuit :
HS1C-R144R-
Main Circuit :
Monitor Circuit :
Main Circuit :
HS1C-R244R-
Main Circuit :
Main Circuit :
HS1C-R344R-
Monitor Circuit :
CAUTION
*7 The Actuator is inserted , and HS1C is locked.
Operation Cycle
Type
Main Circuit
HS1C-
44R-
Auxiliary Circuit
Solenoid Power
Type
Main Circuit
HS1C-
144R-
Auxiliary Circuit
Solenoid Power
Type
Main Circuit
HS1C-
244R-
Auxiliary Circuit
Solenoid Power
Type
Main Circuit
HS1C-
344R-
Auxiliary Circuit
Solenoid Power
Contact Configuration *7
Door monitor Lock monitor
(
-
)
(
+
)
(
-
8
5
6
3
4
1
1
2
3
4
1
2
3
4
1
2
3
4
1
2
Closed
Closed
3-4 : Closed
3-4 : Open
1-2 : Open
1-2 : Closed
5-6 : Off
5-6 : On
3-4 : Closed
3-4 : Open
1-2 : Open
1-2 : Open
5-6 : Off
5-6 : On
3-4 : Closed
3-4 : Open
1-2 : Closed
1-2 : Open
5-6 : Off
5-6 : On
3-4 : Closed
3-4 : Open
1-2 : Closed
1-2 : Closed
5-6 : Off
5-6 : On
• Door is locked.
• Door is unlocked.
• The machine can
• The machine can
• The machine can
be operated.
not be operated.
Solenoid Type Safety Switch
6
Wiring
Wire Length inside the Safety Switch
)
Wire Length :
L1(mm)
Wire Stripping
Leng h : L2 (mm)
Recommended Wire Core Size
Screw Terminal No.1, 2, 5, 6, 7, 8 : 0.5 to 0.75 mm
Screw Terminal No 3, 4, E
Applicable Crimping Terminal
Screw Terminal No. 1 to 6 : Direct Wiring Using a solid or standed wire
Note : When using a stranded wire, make sure that adjoining terminals are not
short-circuited with protruding core wires. Also, do not solder the core wires to
Open
avoid protruding wires.
3-4 : Open
1-2 : Closed
<Ferrules> : Recommended ferrules (Phoenix Contact)
5-6 : Off
Type No.
3-4 : Open
AI 0.75-8 GY
1-2 : Closed
AI 1.0-8 RD
5-6 : Off
AI 1.5-8 BK
3-4 : Open
Crimping Tool : CRIMPFOX UD6
1-2 : Open
5-6 : Off
Screw Terminal No. 7,8:
3-4 : Open
Terminal Screw (M3.5)
1-2 : Open
5-6 : Off
3.6mm min.
not be operated.
L1
Φ3.6mm min.
Approx. 4mm
Wire
Insulation Tube
Crimping Terminal
Applicable Connectors
Use a connector with a degree of protection IP67.
• When using flexible conduit and metal connector
Applicable Flexible Conduit Example
: Type VF-03 (made by Nihon Flex)
Applicable Metal Connector Example (G1/2)
: Type RLC-103 (made by Nihon Flex)
• When using plastic connector, metal connector and multi-core cable
(G1/2)
Applicable Plastic Connector Example : Type SCS-10
Applicable Metal Connector Example : Type ALS-16
Note : Confirm the outside diameter of the multi-core cable, the connector type
depends on the outside diameter of multi-core cable.
Screw
Through Conduit Hole
Terminal
1
2
3
No.
30±2
45±2
70±2
1
30±2
50±2
65±2
2
25±2
55±2
60±2
3
25±2
60±2
55±2
4
5
30±2
65±2
50±2
6
30±2
70±2
45±2
7
65±2
35±2
110±2
8
65±2
110±2
35±2
E
85±2
45±2
45±2
7±1
Safety Switch
L2
2
: 1.0 to 1.25 mm
2
Applicable Wire
0.5 to 0.75mm
2
0.75 to 1.0mm
2
1.0 to 1.5mm
2
Screw Terminal No. E:
Ground Terminal Screw (M4)
3.5mm max.
3.5mm min.
L1
Φ4.1mm min.
Note : Make sure to use an insulation tube
on the crimping terminal.
2016.08
B-1909-1(0)
Connector
L1
3.8mm max.
Conduit Thread
9mm max.
(made by Seiwa Electric)
□□
(made by Nihon Frex)
( 3 / 5 )