MP08A Receiver
Installation
MP08 input and output configuration
©
Danfoss | March 2022
This receiver has one analog input IN 0-10V (without isolation) or IN 0-20mA (without isolation). These
inputs share the same hardware/pins and each one is selected by an internal jumper.
The two inputs cannot be live together at the same time.
The MP08 Receiver does have an current limitation of 7.5 Amps, however it does not include a Fuse. It is
highly recommended to install an External fuse.
MP08A digital outputs
The digital output group K1-K4 have a common contact at pin B1 of the connector. This pin is connected
to pin B12 (stop) for powering up the group of outputs. Maximum of 2A per output.
DEUTSCH connector
K1
K2
K3
K4
As an alternative, this group of outputs (K1-K4) can be connected directly to the external general power
supply in order to provide a higher capacity of current.
DEUTSCH connector
K1
K2
K3
K4
Pin B12
Emergency Stop Output
external connection
Pin B1
Pin A12
Pin A1
Pin A11
Pin A2
Pin B12
Emergency Stop Output
external power supply
Pin B1
Pin A12
Pin A1
Pin A11
Pin A2