Advertisement

Quick Links

Vestil Manufacturing Corporation
2999 North Wayne St., Angola, IN 46703
Phone (260) 665-7586 • Fax (260) 665-1339
E-mail: sales@vestil.com Website: www.vestil.com
Ergonomic Solutions
Contents
Safety Precautions .......................................... 1
Receiving Instructions ..................................... 1
Warranty .......................................................... 1
Parts List for HYD-5 & HYD-10 .................... 2-3
Troubleshooting Guide for HYD-5 & HYD-10 .. 4

SAFETY PRECAUTIONS

Read owner's manual completely before operating unit!
• Never exceed the maximum loading capacity of 880 pounds.
• Stand clear of load while loading and unloading.
• Load must be evenly distributed on deck to insure stability.
• Use caution in moving a loaded unit; avoid obstructions and
floor defects.
• Always apply wheel brakes when unit is not in motion.
• Never go under deck if there is weight on unit.
• Do not continue to pump on the foot lever if the deck is not
raising.
• Remove weight before working on unit.
• Do not use brake fluid or jack oils. Use AW-32 hydraulic oil
or equivalent.
• Use only replacement parts supplied or approved by the
manufacturer.
• Consult factory before performing any modification to the
original equipment.
• Make sure all operator safety labels are in place (p.11).

RECEIVING INSTRUCTIONS

Every unit is thoroughly tested and inspected prior to
shipment. However, it is possible that the unit may incur
damage during transit. If damage is noticed when unloading,
make a note of it on the BILL OF LADING. Remove all packing
and strapping material, then inspect the unit again for damage.
IF DAMAGE IS EVIDENT, FILE A CLAIM WITH THE CAR-
RIER IMMEDIATELY!
Revised 0507
A company dedicated to solving ergonomic and material
handling problems since 1955.
OWNER'S
MANUAL
Bill of Materials for HYD-10-DC ..................... 8
Warning Label Identification ......................... 11

WARRANTY

This product is warranted for 90 DAYS from date
of purchase to be free of manufacturing defects in material
and workmanship. The manufacturer's obligation hereun-
der is limited to repairing such products during the warranty
period, provided the product is sent prepaid back to the
factory.
This warranty does not cover normal wear of parts
or damage resulting from any of the following: negligent
use or misuse of the product, use or application contrary
to installation instructions, or disassembly, repair or alter-
ation by any person prior to authorization from a factory
representative.
HEFTI-LIFT
MODEL HYD 5 & HYD-10
33-126-101
E
N
G
L
I
S
H
E
S
P
A
N
O
L
F
R
A
N
Ç
A
I
S
1

Advertisement

Table of Contents
loading

Summary of Contents for Vestil HYD-5

  • Page 1: Table Of Contents

    Receiving Instructions ........1 Hydraulic Diagram for HYD-10-DC ....9 Warranty ............1 Troubleshooting Guide for HYD-10-DC ..10 Parts List for HYD-5 & HYD-10 ....2-3 Warning Label Identification ......11 Troubleshooting Guide for HYD-5 & HYD-10 .. 4 SAFETY PRECAUTIONS...
  • Page 2: Parts List For Hyd-5 & Hyd-10

    PARTS LIST HEFTI-LIFT • HYD-5 & HYD-10 PARTS IDENTIFICATION HEFTI-LIFT MODEL HYD-5 & HYD-10 ITEM HYD-5 HYD-10 DESCRIPTION QTY. QTY. ENGINEER NO. ENGINEER NO. 33-154-004 33-154-016 Chain Cover 33-154-005 33-154-017 Chain Assembly 33-154-006 33-154-006 Brake Assembly 33-154-032 33-514-018 Mast 33-154-007...
  • Page 3 FOOT PUMP HEFTI-LIFT • HYD-5 & HYD-10 PARTS IDENTIFICATION FOOT PUMP (HEFTI-LIFT) HYD-5 HYD-5 HYD-10 HYD-10 ITEM ENGINEER NO. PART NO. ENGINEER NO. PART NO. QTY. DESCRIPTION 33-154-010 HYD5-FP01 33-154-010 HYD10-FP01 Release Knob Assembly 33-154-011 HYD5-FP02 33-154-018 HYD10-FP02 Pump Assembly...
  • Page 4 Troubleshooting Quick Reference Guide for HYD-5 & HYD-10 (For further information please contact the factory) WARNING! BEFORE PERFORMING ANY MAINTENANCE WORK ALWAYS ENSURE THAT THE DECK/FORKS ARE IN LOWER POSITION Observation Possible Cause Remedy Deck/forks do not raise. Excessive load.
  • Page 5: Operating Instructions For Hyd-10-Dc

    OPERATING INSTRUCTIONS - HYD-10-DC Ensure that all employees involved in the operation of this lift understand and follow the following instructions! Loading: The load rating, in pounds, is shown on the machine dataplate. It indicates the net capacity of the lift with the load centered and evenly distributed on the platform.
  • Page 6 ADDITIONAL INSTRUCTIONS FOR BATTERY-POWERED UNITS WARNING! Working with or near lead acid batteries is dangerous. Batteries contain sulfuric acid and produce explosive gases. A battery explosion could result in loss of eyesight or serious burns. Do not smoke or allow a spark or flame near batteries. Charge batteries in locations which are clean, dry, and well-ventilated.
  • Page 7: Electrical Diagram For Hyd-10-Dc

    ELECTRICAL DIAGRAM • HYD-10-DC Warning: Care should be taken to identify all potential hazards and comply with applicable safety procedures before begin- ning work. Fully lower or securely support the platform, and ensure that system pressure and power have been removed, before attempting to work on any of the hydraulic components! Only qualified individuals trained to understand mechanical devices and their associated electrical and hydraulic circuits should attempt troubleshooting and repair of this equipment.
  • Page 8: Bill Of Materials For Hyd-10-Dc

    ELECTRICAL BILL OF MATERIALS • HYD-10-DC When contacting the factory for replacement parts or for any correspondence, please provide the products serial number. Only qualified individuals trained to understand mechanical devices and their associated electrical and hydraulic circuits should attempt troubleshooting and repair of this equipment. ITEM PART NUMBER...
  • Page 9: Hydraulic Diagram For Hyd-10-Dc

    HYDRAULIC DIAGRAM • LIFT-HOLD-LOWER CIRCUITS • Care should be taken to identify all potential hazards and comply with applicable safety procedures before beginning work. • Raise the lift and install the maintenance props before beginning any inspections or work on the unit. •...
  • Page 10: Troubleshooting Guide For Hyd-10-Dc

    TROUBLESHOOTING GUIDE HYD-10-DC • WARNING: Care should be taken to identify all potential hazards and comply with all applicable safety procedures before beginning troubleshooting or repairs. • CAUTION: Before performing any troubleshooting or repairs, the load must be removed from the platform. Then either raise the platform and install maintenance props or fully lower the platform to the floor.
  • Page 11: Warning Label Identification

    WARNING LABEL IDENTIFICATION MAKE SURE ALL WARNING LABELS ARE IN PLACE! * Product safety signs or labels should be periodically inspected and cleaned by the product users as necessary to maintain good legibility for safe viewing distance. ANSI 535.4 (10.21) Contact manufacturer for replacement labels.

This manual is also suitable for:

Hyd-10

Table of Contents