Vestil EHLT-E Manual

Vestil EHLT-E Manual

Electric-hydraulic scissor lift tables

Advertisement

Quick Links

TABLE OF CONTENTS
EHLT-E Electric-Hydraulic Scissor Lift Tables
Receiving Instructions
After delivery, remove the packaging from the product. Inspect the product closely to determine
whether it sustained damage during transport. If damage is discovered, record a complete description of
it on the bill of lading. If the product is undamaged, discard the packaging.
NOTE: The end-user is solely responsible for confirming that product design, use, and maintenance comply
with laws, regulations, codes, and mandatory standards applied where the product is used.
Technical Service & Replacement Parts
For answers to questions not addressed in these instructions and to order replacement parts, labels,
and accessories, call our Technical Service and Parts Department at (260) 665-7586. The Department can
also be contacted online at https://www.vestil.com/page-parts-request.php.
Electronic Copies of Instruction Manuals
Additional copies of this instruction manual may be downloaded from
manuals.php.
Signal
Words..........................................................................................................................
Safety
Instructions..................................................................................................................
Exploded View
and
Bill of
Electric Circuit
Diagram: 115VAC...........................................................................................
Motor Lead
Connections.......................................................................................................
Control Voltage
Transformer...................................................................................................
Power Unit
Subassembly:
Hydraulic
Schematic.............................................................................................................
Installing the
Table.................................................................................................................
Record of Satisfactory
Condition............................................................................................
Operating the
Table...............................................................................................................
Inspecting and Maintaining the
Solenoid Valve
Maintenance................................................................................................
Bleeding Air from the Hydraulic
Troubleshooting
Guide...........................................................................................................
Labeling
Diagram.........................................................................................................................
Limited
Warranty...................................................................................................................
TABLE OF CONTENTS
Rev. 11/28/2022
2999 North Wayne Street, P.O. Box 507, Angola, IN 46703
Telephone: (260) 665-7586 -or- Toll Free (800) 348-0868
Web:
www.vestil.com
Table of Contents
Materials.........................................................................................
Power
Unit;
Manifold
Assembly..........................................................
Table.....................................................................................
Cylinder..................................................................................
Copyright 2022 Vestil Manufacturing Co.
Vestil Manufacturing Co.
Fax: (260) 665-1339
e-mail:
EHLT-E MANUAL
info@vestil.com
https://www.vestil.com/page-
Page
11,
12,
Page 1 of 17
2
2
3,
4
5
7
7
8
9
9,
10
11
12
13
14
14
15
16
17

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EHLT-E and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vestil EHLT-E

  • Page 1 Web: www.vestil.com e-mail: info@vestil.com EHLT-E Electric-Hydraulic Scissor Lift Tables Receiving Instructions After delivery, remove the packaging from the product. Inspect the product closely to determine whether it sustained damage during transport. If damage is discovered, record a complete description of it on the bill of lading.
  • Page 2: Signal Words

    SAFETY INSTRUCTIONS Vestil strives to identify all hazards associated with the use of our products. However, material handling is dangerous and no manual can address every risk. The most effective way to avoid injury is for the end-user to exercise sound judgment whenever using this product.
  • Page 3 TABLE OF CONTENTS Rev. 11/28/2022 EHLT-E MANUAL EXPLODED VIEW: EHLT-E (01-006-525) TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co. Page 3 of 17...
  • Page 4 TABLE OF CONTENTS Rev. 11/28/2022 EHLT-E MANUAL BILL OF MATERIALS: EHLT-E (01-006-525) ITEM PART NO. DESCRIPTION QTY. 01-002-525 FINAL ASSEMBLY W/O POWER UNIT 01-514-204 WELDMENT, FRAME 01-513-029 WELDMENT, DECK 01-510-100 WELDMENT, LEG, SCISSOR, OUTER 01-510-097 WELDMENT, LEG, SCISSOR, INNER 01-527-002 ROLLER, ASSY Ø2 1/4"...
  • Page 5: Electric Circuit Diagrams

    115 VAC, Single-Phase Electric Circuit Diagram (01-124-025) Note: Overcurrent & short circuit protection and disconnect must be provided by end user. TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co. Page 5 of 17...
  • Page 6 Note: Overcurrent & short circuit protection and disconnect must be provided by end user. 3-Phase Electric Circuit Diagram (01-124-027) Note: Overcurrent & short circuit protection and disconnect must be provided by end user. TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co. Page 6 of 17...
  • Page 7: Motor Lead Connections

    When changing the motor voltage configuration, you must also change the WARNING configuration of the control transformer to match the motor voltage. Control Voltage Transformer (01129001 Rev. G). TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co. Page 7 of 17...
  • Page 8 O-RING, MANIFOLD, 3/4" OD 99-153-006 VALVE, PRESSURE RELIEF, 210 BAR CHECK VALVE, SIZE 08, NOSE-IN/SIDE- 99-153-011 99-153-015 VALVE SOLENOID, STANDARD 99-153- FLOW CONTROL, PRES. COMP., 1.0 GAL. 038-001 TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co. Page 8 of 17...
  • Page 9: Hydraulic Schematic

    Motor overload protection is provided by a thermostat built into the motor. TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co. Page 9 of 17...
  • Page 10 9. Clean the surfaces of the table, e.g. remove debris, oil. Verify that all labels applied to the table are in satisfactory condition. See RECORD; also see LABELING DIAGRAM on p. 17. TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co. Page 10 of 17...
  • Page 11: Operating The Table

    Maintenance observe, the safety rules and practices in this section. prop Standard EHLT-E series lift tables are suitable for use indoors in most non-classified industrial locations and many commercial Scissor leg locations.
  • Page 12 If any item is in need of repair or otherwise contributes to an unsafe condition, remove the lift table from service until it has been restored to a safe operating condition. The standard EHLT-E scissor lift table is provided with a handheld pushbutton control that connects to an electric-hydraulic power unit.
  • Page 13 150 SUS at 100°F (ISO 32 cSt @ 40°C) or Dexron transmission fluid. TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co. Page 13 of 17...
  • Page 14 5. For multi-cylinder lift tables, it will be necessary to open the bleeder valves on all NOTE: Your model might have only 1 maintenance prop. cylinders simultaneously in order to bleed the valves. TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co. Page 14 of 17...
  • Page 15: Troubleshooting Guide

    Flow control valve spool sticking. “Inspecting and Maintaining” section. Platform lowers too Remove and inspect valves. Clean per instructions Flow control valve spool sticking. quickly. “Inspecting and Maintaining” section. TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co. Page 15 of 17...
  • Page 16: Labeling Diagram

    G: Label 204 both sides of base frame H: Label 269 both sides of base frame Data Tag: Label 1153 covered with 770 applied to rear flange of platform TABLE OF CONTENTS Copyright 2022 Vestil Manufacturing Co. Page 16 of 17...
  • Page 17: Limited Warranty

    The warranty period for original dynamic components is 1 year. For wearing parts, the warranty period is 90 days. Both warranty periods begin on the date Vestil ships the product to the Warrantee. If the product was purchased from an authorized distributor, the periods begin when the distributor ships the product.

Table of Contents