IMO Jaguar VXM Instruction Manual page 120

Advertisement

The following functions are changed or added, refer to section 5-1
Function No.
NAME
F13
Electric thermal O/L relay (for braking-resistor)
F14
Restart mode after momentary power failure(operation selection)
F25
Stop frequency
F41
Torque limit1 (braking)
E17
Torque limit2 (braking)
E01 to E09
X1 to X9 terminal function
E20 t0 E24
Y1 to Y4, Y5A and Y5C terminal function
H07
ACC/DEC pattern (mode select)
UXX
User functions
5. Function Select
5-1 Function Select List
F : Fundamental Functions
Func
NAME
No.
F25 Stop frequency
E : Extension Terminal Functions
Func
NAME
No.
E01 X1 terminal function
E02 X2 terminal function
E03 X3 terminal function
E04 X4 terminal function
E05 X5 terminal function
E06 X6 terminal function
E07 X7 terminal function
E08 X8 terminal function
E09 X9 terminal function
E20 Y1 terminal function
E21 Y2 terminal function
E22 Y3 terminal function
E23 Y4 terminal function
E24 Y5A and Y5C terminal function
U : User Functions
Func
NAME
No.
U01 Maximum compensation frequency
during braking torque limit
U02 1st S-shape level at acceleration
U03 2nd S-shape level at acceleration
U04 1st S-shape level at deceleration
U05 2nd S-shape level at deceleration
U08 Main DC link
(initial value)
U09
capacitor (measured value
U10 PC board capacitor powered on time
U11 Cooling fan operating time
U13 Magnetize current vibration
damping gain
U15 Slip compensation filter
time constant
U23 Integrall gain of continuous
operation at power failure
U24 Proportionall gain of continuous
operation at power failure
U48 Input phase loss protection
U49 RS485 protocol selection
U56 Speed agreement
(Detection width)
U57
/ PG error
(Detection timer)
U58 PG error selection
U59 Braking-resistor function select
U60 Regeneration avoidance
at deceleration
U61 Voltage detect offset and
gain adjustment
Note: U-functions are displayed on the keypad panel ROM version "K08000" or later.
5-64
Change of added contents
"External braking resistor" of set value 2 means the resistor of type "DB***-2C/4C".
In case of set value 2 or 3, setting of U23, U24 becomes effective.
Setting range: changed from "0.1 to 6.0Hz" to "0.1 to 60.0Hz".
U01 (Maximum compensation frequency during braking torque) becomes effective.
In case of 0% selected (regeneration avoidance), U60 becomes effective.
Setting range: changed from "0 to 32" to "0 to 35".
Setting range: changed from "0 to 34" to "0 to 37".
"Sharp of S-shape" of set value 2 is changed to "variable of S-shape".
New addition
LCD Display
Setting range
F25
STOP Hz
0.1 to 60.0HZ
LCD Display
Setting range
0 to 35
E01
X1 FUNC
E02
X2 FUNC
E03
X3 FUNC
E04
X4 FUNC
E05
X5 FUNC
E06
X6 FUNC
E07
X7 FUNC
E08
X8 FUNC
E09
X9 FUNC
E20
Y1 FUNC
0 to 37
E21
Y2 FUNC
E22
Y3 FUNC
E23
Y4 FUNC
E24
Y5 FUNC
LCD Display
Setting range
USER 01
0 to 65535
U01
U02
USER 02
1 to 50%
U03
USER 03
1 to 50%
U04
USER 04
1 to 50%
U05
USER 05
1 to 50%
U08
USER 08
0 to 65535
U09
USER 09
0 to 65535
U10
USER 10
0 to 65535h
U11
USER 11
0 to 65535h
U13
USER 13
0 to 32767
U15
USER 15
0 to 32767
U23
USER 23
0 to 65535
U24
USER 24
0 to 65535
U48
USER 48
0, 1, 2
U49
USER 49
0, 1
U56
USER 56
0 to 50%
U57
USER 57
0.0 to 10.0s
U58
USER 58
0, 1
U59
USER 59
00 to A8(HEX)
U60
USER 60
0, 1
U61
USER 61
--22kW : 0(Fixed.)
30kW-- : 0, 1, 2
116
Factory Setting
Min.
Unit
Unit
--22kW
30kW--
Hz
0.1
0.2
Factory Setting
Min.
Unit
Unit
--22kW
30kW--
0
1
2
3
_
_
4
5
6
7
8
0
1
_
_
2
7
10
Factory Setting
Min.
Unit
Unit
--22kW
30kW--
_
1
75
%
1
10
%
1
10
%
1
10
%
1
10
_
1
xxxx
_
1
0
h
1
0
h
1
0
_
1
819
410
_
1
556
546
_
1
1738
1000
_
1
1024
1000
_
1
--55kW
75kW--
0
1
_
_
0
%
1
10
s
0.1
0.5
_
_
1
_
1
00
_
_
0
_
_
0
Change
User
Remark
during op
Set Value
NA
Change
User
Remark
during op
Set Value
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
Change
User
Remark
during op
Set Value
A
NA
NA
NA
NA
A
A
A
A
A
A
A
A
NA
NA
A
A
NA
NA
NA
A
5 Function Selection