TROUBLESHOOTING

In case the display shows one of the following error or alarm codes, act accordingly:
Code
Meaning
016
Tank does not
reach the set
pressure
018
Pressure keeps
dropping
019
Misfire
(system error)
121
Orientation of
device out of
safe bounds
123
Pressure too
high
206
Pressure not
rising
Always contact MAGIC FX if any malfunctions or errors occur that cannot be solved
with the instructions as described in this manual.
Solution
• Make sure the vent valve is entirely closed.
• If the problem is not solved contact MAGIC FX.
• Make sure the vent valve is entirely closed.
• If the problem is not solved contact MAGIC FX.
• Open the vent valve and make sure the gauge
pressure is 0 bar.
• Close the vent valve.
• Press the compressor on/off button to pressurize
again.
• Wait until the STADIUMSHOT III has built up the set
pressure.
• Fire again.
• If the problem is not solved contact MAGIC FX.
• The machine is tilted more than allowed. Turn the
machine to a level position.
• Open the vent valve.
• Close the vent valve when the warning has
disappeared.
• Make sure the vent valve is entirely closed.
• Press the compressor on/off button to pressurize
again.
• If the problem is not solved contact MAGIC FX.
MAGICFX
STADIUMSHOT III — User and Installation Manual
®
Troubleshooting