HYDRAULIC INSTALLATION
HYDRAULIC INSTALLATION
Widro 85 is designed to install to a water circuit with
Widro 85 is designed to install to a water circuit with
open expansion vessel.
open expansion vessel.
Widro 85 can be installed on circuits with open expansion
Widro 85 can be installed on circuits with open expansion
vessels (check local regulations), providing the fittings
vessels (check local regulations), providing the fittings
are connected to the thermal discharge valve of the coil.
are connected to the thermal discharge valve of the coil.
The appliance must be correctly sized,
The appliance must be correctly sized,
installed,
installed,
maintained
maintained
in compliance with local and national
in compliance with local and national
law and European regulations. For
law and European regulations. For
the installation, and for anything not
the installation, and for anything not
specifically indicated in the manual,
specifically indicated in the manual,
observe local regulations.
observe local regulations.
HYDRAULIC CONNECTIONS
The hydraulic connections depend on the type of
system.
However, there are a few "general rules":
The presence of a puffer (inertial storage tank) is
recommended but not mandatory. Its advantage is
that it releases the product from "sudden" requests
from the system and can be integrated with other
heat sources. It reduces fuel consumption and
increases the efficiency of the system.
The return temperature of water must be higher
than at least 50–55 °C to prevent condensate from
forming.
An accumulator (tank) is needed to heat low-
temperature radiant panels and must be installed
according to the panel manufacturer's instructions.
The material used in the circuit must be suitable to
withstand overheating.
Direct plumbing to radiators prevents proper
operation, owing to the small diameter of their pipes.
The return temperature of water must be higher than at least 50–55 °C to prevent condensate from
forming.
An anti-condensation system is essential and failure to install one will invalidate the warranty, on the basis
of incorrect installation.
INSTALLATION
and
and
operated
operated
EXTERNAL WATER CIRCUIT KITS (OPTIONAL)
EXTERNAL WATER CIRCUIT KITS (OPTIONAL)
FOR OPEN/CLOSED EXPANSION VESSEL
FOR OPEN/CLOSED EXPANSION VESSEL
For simple installation, Edilkamin offers pre-assembled
For simple installation, Edilkamin offers pre-assembled
kits for installation outside the product.
kits for installation outside the product.
The product you require depends on the type of circuit
The product you require depends on the type of circuit
you are installing.
you are installing.
INSTALLER
Never light the fire in the product (even to
test it) when the circuit is dry (no water);
doing so may irreparably damage the
appliance.
21