THE SMOKE DUCT
THE SMOKE DUCT
• if it is metal, it must have CE marking (EN 1856-2) or
some similar national standard marking;
• may not be made of flexible metal material;
• in order to check the flow, it is recommended to use
a damper if the draught is above 25 Pa.
THE FLUE:
THE FLUE
it must have a draught capable of creating
depressurisation, which is ideally around 12 Pa.
Lower draughts may lead to leaks of smoke when
the door is opened; higher values tend to generate
fast combustion and reduced efficiency
must be correctly sized to satisfy the requirements
for flue gas discharging (EN 13384-1)
should preferably be insulated, in steel with a
circular internal section. If rectangular, the inner
corners must have a radius of not less than 20
mm, with a ratio of the internal dimensions of <1.5
must normally be at least 4 metres in vertical length
must be waterproof and thermally insulated to
ensure proper draught
preferably provide a collection chamber for
unburnt fuel and condensates
must be at least in the T400 category with
appropriate resistance against soot igniting
18
if pre-existing, must be clean, to prevent fire
hazards.
Infiltration of water from condensation
through the flue must be strictly avoided.
If necessary, an anti-condensate ring
should be installed. Ask your chimney
sweep for details.
Damage
condensation is excluded from the warranty.
INSTALLATION
caused
by
water
THE CHIMNEY POT
THE CHIMNEY POT
must be anti-downdraught
must have an internal cross section equivalent to
that of the flue and a fumes outlet at least double
that of the interior of the flue
for dual flues (which should be spaced at least 2
m apart) the chimney pot of the flue receiving the
fumes from the solid fuel appliance or that from
the higher storey, must be at least 50 cm higher
needs to beyond the back flow zone
it must allow for maintenance of the chimney
from
INSTALLER