3.1.3

Analogic Data Format

Figure 3-3 shows the Analogic continuous output data format.
<STX> <nnnnnnnnn> <ttttttttt> <SP> <S> <UNIT> <SP> <TERM>
STX (02h)
Net Weight: 9 characters, 7
active weight digits, no leading
zeroes, decimal point, negative
sign precedes first active digit.
Tare Weight: 9 characters, 7
active weight digits, no leading
zeroes, decimal point, negative
sign precedes first active digit.
3.1.4

Cardinal Data Format

Figure 3-4 shows the Cardinal continuous output data format.
<CR> <POL> <wwwwwww> <S> <SP> <UNIT> <SP> <G/N> <SP> <SP> <ETX>
Polarity:
<Space> = Positive
< – > = Negative
Carriage
return
Seven digits of weight data, including
decimal point. No leading zero
suppression.
3.2

Serial Data Input

Some weight indicators have multiple outputs. Some can have two or more RS232 outputs or current loop
outputs which can be active or passive. The preferred interface is an active current loop output from the weight
indicator. A passive current loop is second in preference, and RS232 being the least desirable. The transmitted
data must be continuous and demand ports are unusable. Information is explained in further detail in the
following sections.
3.2.1

RS232 C

Data is transmitted as a voltage and alternates between +10 VDC and -11 VDC. Hybrid RS232 signals can swing
between other voltage ranges as long as the positive swing is greater than 4 VDC and the negative is less than - 1
VDC. RS232 is ground referenced and therefore, connects the ground planes of the sending and receiving
instruments. RS232 should never be run more than 50 feet. It may work, but it may not work well or all the time.
Long RS232 data cables can act as a conduit for lightening or other electrical noise to the instrument. If you need
longer cable runs, use a 20 mA current loop.
14
EL232 XCPD Installation Manual
Space
character
Status <S> is the sum of:
1 = In range
2 = Standstill
4 = Center of Zero
8 = Net mode
For example:
In range = 1
Standstill = 2
Net Mode = 8
Figure 3-3. Analogic Continuous Output Data Format
Space
character
Status:
M = motion
O = out of range
<space> = for none
of the above
Figure 3-4. Cardinal Continuous Output Data Format
Space
character
0 = kilogram
1 = gram
2 = pound
3 = ton (short/metric)
4 = ounce
5 = none
6 = grain
<S> = B (hex)
G for Gross
N for Net
Space
character
G = gram
K = kilogram
L = pound
T = ton (short)
<Space> = ton (metric),
grain, ounce or none
<CR> or
<LF> or
<CR> <LF>
ETX (03h)
Space character (2)