Initial Start-Up - KNF UFK 1.1100 EX Installation Instructions Manual

Diaphragm pump
Table of Contents

Advertisement

Installation Instructions UFK 1.1100 Ex
KNF, Inc. UFK1.1100 Ex.docx
11

4 Initial start-up

The product must not be started up until it has been ensured that
the machine in which the product is to be installed meets the
requirements of the Machinery Directive 2006/42/EC, if applicable.
Danger that the fluid system could rupture due to excess
pressure
The pump builds up pressure. With a closed system, the max.
permitted operating pressure can be exceeded. This may cause
injuries to personnel, or damage to the pump or the system.
 Prevent operation against a closed system.
 In the case of parts that are in contact with the fluid, use
only those that are designed to withstand at least the op-
erating pressure of the pump.
 If necessary, take suitable measures to limit the maximum
system pressure.
Danger of unexpected chemical reactions with water
Residues of water in the pump that come from testing in the
factory may react with the transferred medium.
 Before starting the pump for the first time, rinse it with a
medium that is uncritical as regards water.