USER SAFETY

IMPORTANT SAFETY INSTRUCTIONS
READ AND SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
WARNING - TO REDUCE THE RISK OF
FIRE, ELECTRIC SHOCK, OR INJURY TO
PERSONS, OBSERVE THE FOLLOWING:
a) Use this unit only in a manner intended by
the manufacturer. If you have questions, contact
the manufacturer.
b) Before servicing or cleaning unit, switch
power off at service panel and lock the service
disconnecting means to prevent power from
being switched on accidentally. When the
service disconnecting means cannot be locked,
securely fasten a prominent warning device,
such as a tag, to the service panel.
IMPORTANT NOTES!
In areas where temperatures can cause water
supply pipes to freeze, a drain down facility
should be provided during the installation. This
drain down facility must be activated prior to
freezing conditions, to avoid possible damage
to the cooler components.
New hose sets supplied with the appliance are
to be used.
Old hose sets (from previous installations)
should not be re-used.
As with any product that has moving parts
or is subject to wear and tear, it is VERY
IMPORTANT that you maintain the product
and have it regularly serviced. It is a condition
of warranty cover for your product that you
comply with all of the maintenance and
service requirements set out in the Owner's
Manual. Compliance with these requirements
will prolong the life of your product. Further,
it is also a condition of warranty cover that
each item in the Maintenance Schedule in
the Owner's Manual is performed with the
frequency indicated, by a qualified, licensed
technician, and that the Maintenance Schedule
is properly filled out (i.e. names, signature, date,
and action taken) when the item is completed.
ANY FAILURE TO CARRY OUT THE
REQUIRED MAINTENANCE AND
SERVICING REQUIREMENTS, AND ANY
FAILURE TO PROPERLY FILL OUT THE
MAINTENANCE SCHEDULE, WILL VOID
YOUR WARRANTY.
|
16

OPERATING INSTRUCTIONS

OPERATING YOUR COOLER

At Seeley International, we manufacture evaporative coolers
from the highest quality materials, and we have designed the
product to provide many years of economical, trouble-free
cooling.
To provide efficient cooling or ventilation the building must have
sufficient exhaust openings to the outside of the building.
To assist air flow, open windows and doors that are farthest
from the outlet vent in each room. In these rooms, provide an
exhaust opening 2 times the vent size of the room.
Where the design of the building prevents adequate exhaust,
consideration should be given to the provision of mechanical
extractions, such as an exhaust fan.
Your installer will provide the control switch for the cooler and
explain how to use it.

CONTINUOUS BLEED SYSTEM

During operation, the bleed system will drain small amounts of
water. This ensures fresh water is continually added to dilute
salt accumulation in the water caused through evaporation. This
helps keep the air cooler in good condition and ensure optimum
performance. The bleed rate will depend on local operating
conditions and will be set by the installer.

HEALTH REGULATIONS

In some regions, regulations require that evaporative air coolers
be serviced at specific intervals.