INSTALLATION

BLEED FUNNEL

The bleed funnel reduces the accumulation of salts and
minerals in the cooler. It also acts as an overflow and a drain.
Assemble the bleed funnel as shown.
Make sure the bleed funnel is correctly oriented and that the
O-rings are fitted before placing it into the hole. Screw the nut
up tightly by hand underneath the cooler.
Make sure that you use the correct drain adaptor. Drain-
water from the bleed funnel must be carried away to a suitable
discharge point on the building or property in accordance with
local regulations. Do not drain directly onto the roof surface.
The bleed rate required will vary according to water quality,
but should initially be set to the minimum rate as set out in the
table.
Push the remaining plugs into the blind holes provided. In poor
quality water areas where the salt and mineral contents are
high, adjust the bleed rate by inserting one or more extra plugs
than specified in the table.
Note! In some locations due to regulatory requirements, the
use of bleed funnels are not allowed. In these locations ensure
the plugs are not inserted or are removed from the bleed funnel
entirely.
CTA250
1 Plug
ILL970-C
CTA500
2 Plugs

ELECTRICAL REQUIREMENTS

Installation of the cooler must conform to local electrical rules,
regulations and standards.
Important! It is a requirement of Seeley International that all
coolers be connected to a dedicated circuit to the distribution
board, with a separate circuit breaker and incorporate a separate
isolation switch in accordance with the local wiring rules.
The following specifications for the cooler electrical supply are
required: 115V/60Hz Single Phase.
It is up to the installer to provide a controller and mains power
WIRING DIAGRAM (CTA250)
should be wired through the controller.
2 SPEED SINGLE PHASE 115V 60 Hz
A system wiring diagram is provided below
*Wall control not provided by Seeley International. Wiring may change depending on the
type/brand of controller used.
LINE VOLTAGE WIRED TO WALL CONTROL
ELECTRICAL
ENCLOSURE
MOTOR
PUMP
FIELD WIRING
FACTORY WIRING (DO NOT DISTURB)
LINE VOLTAGE WIRED TO COOLER
ELECTRICAL
ENCLOSURE
MOTOR
PUMP
FIELD WIRING
FACTORY WIRING (DO NOT DISTURB)
FIELD TERMINATION (NOT SUPPLIED)
The electrical enclosure contains three separate 3AG/3AB slow
blow fuses for over current protection on each of the active lines
for High/Low Speed and the Pump which are contained within
the DIN rail setup. The fuse ratings are as follows:
CTA500
HIGH
LOW
PUMP
CTA EVAPORATIVE COOLER INSTALLATION MANUAL |
*WALL
CONTROL
FAN
HIGH (C)
CONTROL
OFF
LOW (1)
VENT
PUMP
COOL (2)
CONTROL
HOT WIRE / LINE VOLTAGE
(L1) (black)
COMMON/NEUTRAL (L2) (white)
GROUND/EARTH
(green)
*WALL
CONTROL
FAN
HIGH (C)
CONTROL
OFF
LOW (1)
VENT
PUMP
COOL (2)
CONTROL
HOT WIRE / LINE VOLTAGE
(L1) (black)
COMMON/NEUTRAL (L2)(white)
GROUND/EARTH
(green)
ILL3418-B
ILL3418-B
CTA250
15A
8A
10A
4A
3A
3A
11