  • Page 3: Table Of Contents

    HOW TO USE THE PRODUCT.......... 25 How to use 5 Spd Dig Touch Control Product....26 Use of the LCD Product............ 27 LAMP REPLACEMENT............. 30 16.1 Halogen Lamp Replacement........30 AUTHORIZED SERVICE............ 31 TECHNICAL CHART............33 21.02.2018 4110 HOOD USER GUIDE...
  • Page 4: Input

    The figures in this guideline aim to visually describe the actions. In these figures only one model of the device is illustrated. However, all instructions or figures also represent other models. 4110 HOOD USER GUIDE 21.02.2018...
  • Page 5: Technical Drawing

    Technical Drawing Technical Drawing 21.02.2018 4110 HOOD USER GUIDE...
  • Page 6: Warnings And Safety Measures

    Do not operate your product without filter, and do not remove the filters when the product is in operation. In case of any fire, de-energize the hood and any other cooking devices. (Plug off the appliance or turn off the main switch.) 4110 HOOD USER GUIDE 21.02.2018...
  • Page 7 When electric cooker hood is used simultaneously with devices that use gas or other fuels, there must be sufficient ventilation in the room (might not apply to devices that discharges the air back into the room). 21.02.2018 4110 HOOD USER GUIDE...
  • Page 8: Risk Of Death Risk Of Poisoning

    In such a case, the toxic gases are Fig. 1: Poisoning Danger absorbed from the flue and waste gas channel, and are taken into to door again. Fig. 1 Therefore, adequate fresh air ingress must always be ensured.Fig. 2 Fig. 2 4110 HOOD USER GUIDE 21.02.2018...
  • Page 9 If the device is malfunc- tioning pull the power plug and switch off the circuit breaker. Call customer service. – Water leaking into the device may cause elec- tric shock. High pressure or steam cleaners must not be used. 21.02.2018 4110 HOOD USER GUIDE...
  • Page 10 Repairing must be performed only by the author- ized technical service or authorized experts. NOTICE! If the appliance is faulty or damages, turn off the fuse or unplug the feeder cable of your appliance and call the authorized service. 4110 HOOD USER GUIDE 21.02.2018...
  • Page 11 Never use aggres- sive and abrasive cleaning agents. There is a risk of damage due to condensate liquid backflow. Install the air exit canal with a small downward inclination (1° inclination) from the appliance. 21.02.2018 4110 HOOD USER GUIDE...
  • Page 12: Usage With Or Without Carbon Filter

    You can obtain the accessories required for this process at related Fig. 4: Carbon-Filter Air Circulation outlets, authorized service or via an online sales center. 4110 HOOD USER GUIDE 21.02.2018...
  • Page 13: Carbon Filter Replacement

    2-Rotate the carbon filter clockwise and make sure that it is seated completely.Fig. 5 Fig. 5: AF 100 CARBON FILTER If not seated completely, the carbon filter can fall and damage your product. DANGER! Never wash the carbon filters. Keep carbon filters away from children. 21.02.2018 4110 HOOD USER GUIDE...
  • Page 14: Cleaning And Preventive Maintenance

    As you remove the aluminium filter, hold it with your other hand to prevent it from dropping. As you remove the aluminium filter, in order to prevent the accumulated oil to drip, keep the filter surface parallel to the Fig. 6 floor. 4110 HOOD USER GUIDE 21.02.2018...
  • Page 15: Washing In The Dishwasher

    Soften the stains of the metallic oil filters in hot water with dishwashing detergent. – Use a brush for cleaning and let the liquids on the metal oil filters drain completely. – Rinse the filters well after cleaning. 21.02.2018 4110 HOOD USER GUIDE...
  • Page 16: Location Of The Device

    LOCATION OF THE DEVICE M n 65 cm Max 70 cm Fig. 7: Copy of 4110 min max After completing the installation of hood, the minimum distance must be 65 cm between the product and any electric cooker; and 75 cm between it and any gas ranges or cookers burning other fuels (Fig.
  • Page 17: Installatıon And Unpacking

    Check if there are any damages on your appliance. Shipment damages must be reported to the shipment respon- sible immediately. Visible defects must also be communicated to the seller. Do not let children play with packaging material. 21.02.2018 4110 HOOD USER GUIDE...
  • Page 18: Recommendations On Energy Savings

    Use your product according to its normal speeds. Use at higher speed would cause an increase in the energy consumption. 4110 HOOD USER GUIDE 21.02.2018...
  • Page 19: Package Content

    Hanging bar stabilizing plate Ceiling Hanging Plate User Manual Plastic Flue Fig. 8: CONTENT OF PACKAGE Plastic Flue Adapter (Optional) 10- Remote Control (Optional) 11- Ø10mm Plastic Dowel 12- 5.5x60 Wall Mount Screw 13- 3.5x9.5 Flue Connection Screw 21.02.2018 4110 HOOD USER GUIDE...
  • Page 20: Overview Of The Hood

    OVERVIEW OF THE HOOD OVERVIEW OF THE HOOD 1- Inner Flue 2- Outer Flue 3- Front Panel 4- Aluminium Filter 5- Cooker Lighting Fig. 9 4110 HOOD USER GUIDE 21.02.2018...
  • Page 21: Installation Of Product

    A, B, C, D with Ø10 mm drill (Fig. 10). Insert Ø10 mm plastic dowels (1) into the drilled points A,B,C,D (Fig. 10). Install the Ceiling Connection plate to the ceiling at points A,B,C,D with 5.5x60 screws (3) (Fig. 10). 21.02.2018 4110 HOOD USER GUIDE...
  • Page 22 8 pcs. 3.5 x 9.5 r phillips cylinder head screw (1) (Fig. 11). Install product hanging bars to balance hanging bar bal- ancing components (4) with 6 pcs. 3.5 x 9.5 rysb screw (1) (Fig. 11). Make the air connections of the product (Fig. 11/A). 4110 HOOD USER GUIDE 21.02.2018...
  • Page 23 1- 3.5 x 9.5 Motor Cabin Fixing Screw Remove the sheet metal flue fixing screw (Fig. 12). Lift sheet metal flues up and screw the product to product hanging bars with 3.5 x 9.5 r phillips cylinder head screws (Fig. 13/1). 21.02.2018 4110 HOOD USER GUIDE...
  • Page 24 INSTALLATION OF PRODUCT Let the sheet metal flues to descend. Fig. 14 Fix the perforated internal flue on both sides on the ceiling connection plate with 4 screws (Fig. 14). 4110 HOOD USER GUIDE 21.02.2018...
  • Page 25: How To Use The Product

    "C" signal is required, active motor speed will appear for 1 sec when you press ( ) button and then the motor will resume running. "C" symbol will be displayed after 60 hours of oper- ation is elapsed. 21.02.2018 4110 HOOD USER GUIDE...
  • Page 26: How To Use 5 Spd Dig Touch Control Product

    If operation before deleting the "C" signal is required, active motor speed will appear for 1 sec when you press ( ) button and then the motor will resume running. 4110 HOOD USER GUIDE 21.02.2018...
  • Page 27: Use Of The Lcd Product

    Press any key to deactivate the alarm sound. Lamp Symbol ð While the lamp is active, this symbol will be displayed. Fan Speed Symbol ð Fan Speed Symbol will be low when the speed is low and vice versa. 21.02.2018 4110 HOOD USER GUIDE...
  • Page 28 (that is the hood is not opera- tion). Press and hold key for approx. 5 seconds to set the back light is lit continuously again. 4110 HOOD USER GUIDE 21.02.2018...
  • Page 29 Use of the LCD Product LCD Display Color Values Blue (%) Red (%) Green (%) Color Light Tur- quoise Light Green Green Blue Magenta No-Color Orange 21.02.2018 4110 HOOD USER GUIDE...
  • Page 30: Lamp Replacement

    Fig. 19: Halogen lamp symbol For replacing the halogen lamps, push downwards on the lamp holder from its behind, turn it a little bit counter-clockwise, and take it out downwards.Fig. 20 Fig. 20: Halogen Lamp Replacement 4110 HOOD USER GUIDE 21.02.2018...
  • Page 31: Authorized Service

    The air exhaust flue must be open. weak Flue. The product air inlet is Check Carbon filter In products where carbon filters are used, the carbon weak filter must be replaced once every 3 months under normal conditions. 21.02.2018 4110 HOOD USER GUIDE...
  • Page 32 Does Not Discharge Air Check Carbon filter In products that carbon filters are used, carbon filter (Use without Flue) must be replaced once in 3 months under normal con- ditions. 4110 HOOD USER GUIDE 21.02.2018...
  • Page 33: Technical Chart

    Motor Insulation Class Insulation Class CLASS I This product conforms with Directive 2004/108/EC for Electromag- netic Compatibility and Low Voltage Directive (LVD) 2006/95/EC. This product conforms with the Waste Electrical & Electronic Equipment (WEEE) Directive. 21.02.2018 4110 HOOD USER GUIDE...