Carrier 62E Installation, Start-Up And Service Instructions Manual page 24

Energy recovery ventilators
Table of Contents

Advertisement

62E
UNIT
l/s
1652
1888
LD
pa
114
129
l/s
2360
2832
LG
pa
122
144
l/s
2124
2360
MD
pa
124
139
l/s
2832
3304
MG
pa
124
142
l/s
2596
2832
ND
pa
124
137
l/s
3540
4012
NG
pa
127
142
l/s
2832
3304
PD
pa
119
139
l/s
3776
4248
PG
pa
119
134
l/s
3304
3776
RD
pa
127
144
l/s
4248
4720
RG
pa
122
134
l/s
3776
4248
SD
pa
122
137
l/s
5192
6136
SG
pa
124
144
l/s
4248
4720
TD
pa
127
139
l/s
5664
6608
TG
pa
124
144
l/s
4720
5192
UD
pa
100
134
l/s
6608
7552
UG
pa
127
144
NOTE: Pressure sensing ports are provided on both sides of the
ERV wheel for testing and balancing.
UNITS WITH EZERV CONTROL OPTION — With
the EzERV option, the LCD display will change to show the
amount of air moving through the cabinet in cubic feet per
minute (cfm). The screen is divided into two columns: The left
column showing the amount of outside air (Osa/CFM) and the
right column showing the exhaust air (Ext/CFM). To adjust the
fan speeds, remove the small panel next to the control panel
cover to access the user input controls. See Fig. 16.
Fig. 16 — LCD Display
Balanced Air Option — Press the push button once to bring
up the ERV cfm screen. Turn the knob clockwise to increase or
counterclockwise to decrease the amount of outside air coming
into the building. See Fig. 17. The exhaust airflow will auto-
matically adjust to equal the supply airflow. Press the button
again to return to the main screen. Replace the user control
cover.
Table 6 — Airflow vs. Pressure Drop Across ERV Wheel (cont)
AIRFLOW VS. PRESSURE DROP ACROSS ERV WHEEL
2124
2360
2596
2832
147
162
179
194
3068
3304
3540
3776
154
164
177
187
2596
2832
3068
3304
152
167
179
194
3776
4248
4720
4956
162
179
197
207
3068
3304
3540
3776
147
159
169
182
4484
4956
5428
5900
157
172
187
202
3776
4012
4248
4484
159
169
179
189
4720
5192
5664
6136
147
159
172
187
4248
4720
5192
5428
162
182
199
209
5192
5664
6136
6608
147
159
169
182
4720
5192
5664
6136
152
167
182
197
7080
7552
8024
8496
164
174
184
194
5192
5664
6136
6608
154
167
182
197
7552
8496
8968
9440
162
182
189
199
5664
6136
6608
7080
147
159
172
184
8496
9440 10384 11328 11800 12272 12744 13216 13688 14160 14632 15104 15576 16048 16520
159
177
192
209
a62-384.eps
3068
3304
3540
3776
211
226
244
261
4012
4248
4484
4720
197
209
219
229
3540
3776
4012
4248
207
221
234
249
5192
5428
5664
5900
216
224
234
244
4012
4248
4484
4720
192
204
214
226
6372
6844
7316
7788
216
231
246
261
4720
4956
5192
5428
199
209
219
229
6608
7080
7552
8024
199
211
226
239
5664
5900
6136
6372
216
226
234
244
7080
7552
8024
8496
194
207
216
229
6372
6608
6844
7080
204
211
219
226
8968
9440
9912 10384 10856 11328 11800 12272 12744 13216 13688
204
214
224
234
7080
7552
8024
8496
209
224
236
251
9912 10384 10856 11328 11800 12272 12744 13216 13688 14160 14632
209
216
226
236
7552
8024
8496
8968
197
207
219
231
216
224
231
241
Offset Air Option — Press the push button once to bring up
the outside air cfm screen. Turn the knob clockwise to increase
or counterclockwise to decrease the amount of outside air com-
ing into the building. See Fig. 18.
Fig. 18 — Outside Air Cfm Screen
-386.eps
Press the push button again to bring up the exhaust air offset
screen. A negative exhaust air offset would equate to a smaller
amount of air being exhausted from the building when com-
pared to the outside air being supplied to the building. Adjust
the knob clockwise to increase and counterclockwise to de-
crease the exhaust offset cfm level. See Fig. 19. Press the
24
4012
4248
4484
276
294
304
4956
5192
5428
5664
239
251
261
271
4484
4720
4956
5192
264
276
291
304
6136
6372
6608
6844
251
261
271
279
4956
5192
5428
5664
239
249
261
271
8260
8732
9204
276
291
306
5664
5900
6136
6372
239
249
259
269
8496
8968
9440
9912 10384
251
264
279
291
6608
6844
7080
7316
254
264
271
281
8968
9440
9912 10384 10856 11328
241
254
266
276
7316
7552
7788
8024
234
241
249
256
244
254
264
274
8968
9440
9912 10384
266
279
294
306
246
254
264
274
9440
9912 10384 10856 11328 11800
244
256
269
281
249
256
264
274
Fig. 17 — ERV Cfm Screen
5900
6136
6372
284
294
304
7080
7316
7552
289
299
306
5900
6136
6372
284
294
306
6608
6844
7080
279
289
299
304
7552
7788
8024
289
299
309
289
301
8260
8496
8732
264
271
279
284
294
304
281
291
301
294
306
281
289
296
a62-385.eps