Serial Plate Location; Refrigeration Unit Access; Sealing Merchandiser To Floor - Hussmann FNGSC-A Installation & Operation Manual

Dual temperature self contained island merchandiser
Table of Contents

Advertisement

I
1-4
NSTALLATION

SERIAL PLATE LOCATION

The serial plate is located on the inside of the
merchandiser's display area .
Serial Plate

REFRIGERATION UNIT ACCESS

The lower front panel may be removed by
lifting the panel straight upward and over the
tabs on which it is hanging . For self contained
cases, two screws will have to be removed from
either end of the panel . Make sure all electrical
wiring is secured, and that there is no damage
to the unit from shipment or placement .
Confirm there are no refrigerant leaks during
startup of the case(s) . The panel is installed
by reversing the above procedure . Ensure
merchandiser base is properly installed on case
to prevent air circulation problems .

SEALING MERCHANDISER TO FLOOR

If required by local sanitary codes, or if the
customer desires, merchandisers may be sealed
to the floor . Make sure lower front and rear
panels are still able to be removed to service the
condensing unit when sealing around the case .
P/N 3141959_C
NOTE: Do not allow trim to cover any intake
or discharge grilles located in the lower front
panel . When the merchandiser is equipped
with levelers, sealing to the floor may not be
required . Merchandiser may be relocated to
another location so that floor can be cleaned .
Condensing Unit
Condensing Unit
Electrical Box
Electrical Box
Both Sides
both sides
Remove Central
REMOVE CENTRAL
AND SIDE SCREWS
and Side Screws
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
Condensing Unit
Condensing Unit
(FNGSC8A) Shown