S
3-6
TARTUP

SETPOINT: SETTING AND EDIT LOCK

To display the Setpoint value, press the
label is displayed.
The Setpoint value appears on the display. To change the Setpoint value, press the
Press
set
to confirm the modification.
set
It is possible to disable the keypad on this device.
The keypad can be locked by programming the "LOC" parameter appropriately.
set
With the keypad locked, you can still access the "Machine Status" menu by pressing
it. To disable the keypad lock, repeat the locking procedure.
set

DISPLAY PROBES VALUE

To display the value read by probes connected to the device, press the
the key again when one of the probe-related labels "Pb1...Pb5" press the
probe will appear on the display.
NOTE: The displayed value is read-only and cannot be modified.
KDEPLUS BUTTONS
The KDEPlus keyboard has 4 keys, as shown in the illustration:

KEY-ACTIVATED FUNCTIONS

All models have the UP key set to enable the "Manual Defrost" function.
The DOWN and ESC keys can also be set to activate any other function required by the user.
The parameters for configuring the two keys are:
• H11 = DOWN key configuration
• H33 = ESC key configuration
The values that can be set apply to both keys and the functions that can be activated are:
H32/H33 value
0
1
2
3
4
5
6
set
7
8
P/N 3141959_C
/ O
PERATION
set
key to enter the "Machine Status" menu, then press the
set
UP
1
DOWN
2
Increases
Function to enable
disabled
defrost
reduced set
Light
Energy saving
AUX
Stand-by
Deep cooling cycle
Start/end defrost
U.S. & Canada 1-800-922-1919 • Mexico 1-800-890-2900 • www.hussmann.com
set
set
set
set
set
set
key and enter the "Machine Status" menu, then press
set
key again. The value measured by the associated
set
set
set
set
key again when the "SEt"
and
keys within 15 seconds.
set
to display the Setpoint, but you cannot edit
STANDBY or ESC
3
SET