1-4
installation
MERCHANDISER LEVELING
B
e sure to position merchandisers proper
. Level the merchandiser by all four corners.
ly
Merchandiser(s) must be installed level to
ensure proper operation of the refrigeration
system, and to ensure proper drainage of
defrost water.
OPTIONAL LEGS
NSF
approved legs replace the leg levelers if
®
required by local health codes. The legs raise
the case 6 inches for cleaning purposes. An
optional skirt kit can be provided to snap on
the legs.
SERIAL PLATE LOCATION
The serial plate is located on the interior top,
left side of the merchandiser. It contains all
pertinent information such as model, serial
number, amperage rating, refrigerant type and
charge. This information will be needed to install,
service or order parts for the merchandiser.
Serial Plate
P/N 0545716_G
REFRIGERATION UNIT ACCESS
-
The lower front panel may be removed by
removing screw at bottom and lifting the panel
straight upward and over the tabs on which it
is hanging. The panel is installed by reversing the
above procedure.
Ensure lower front panel is flat against the
floor when installed to prevent air circulation
problems for self contained merchandisers.
Front Panel
SEALING MERCHANDISER TO FLOOR
If required by local sanitary codes, or if the
customer desires, merchandisers may be sealed
to the floor using a vinyl cove base trim. The
size needed will depend on how much variation
there is in the floor, from one end of the
merchandiser to the other. Sealing of the lower
front and rear panels on self contained models
may hamper their removal for servicing or
maintenance of the condensing unit.
NOTE: Do not allow trim to cover any intake
or discharge grilles located in the lower front
panel.
U.S. & Canada 1-800-922-1919 • Mexico 01 800-890-2900 • www.hussmann.com
Controller
Display
Lift up and
out to remove
access panel
Display is mounted on left
side of access panel. Be
careful not to detach cable
from display when removing
access panel.