Siemens CP565AGS0B User Manual And Installation Instructions page 50

Hide thumbs Also See for CP565AGS0B:
Table of Contents

Advertisement

en Installation instructions
WARNING ‒ Risk of injury!
Parts that are accessible during installation
may have sharp edges and may lead to cut-
ting injuries.
▶ Wear protective gloves
WARNING ‒ Risk of fire!
It is dangerous to use an extended power
cord and non-approved adapters.
▶ Do not use extension cables or multiple
socket strips.
▶ If the power cord is too short, contact Cus-
tomer Service.
▶ Only use adapters approved by the manu-
facturer.
21.2 Appliance dimensions
You will find the dimensions of the appliance here
21.3 Fitted units
This appliance is only intended to be fully fitted in a kit-
chen. It is not intended to be used as a tabletop appli-
ance or within a cupboard.
Ensure that the fitted cabinet behind the appliance
does not have a back panel. Maintain a clearance of at
least 35 mm between the wall and the cabinet base or
the rear panel of the cabinet situated above.
Ensure that the fitted cabinet has a ventilation opening
of 50 cm² on the front. To create a ventilation opening,
trim the base panel or fit a ventilation grille.
Ensure that surround units without a ventilation cut-out
have a ventilation opening measuring 200 cm² towards
the rear of the side panels.
Do not cover the ventilation slots and air intake open-
ings.
Ensure that the wall socket is located in the hatched
area
or outside of the installation space.
50
Secure any unsecured units to the wall using a stand-
ard bracket
⁠ .
21.4 Installation below a worktop
Observe the installation dimensions and the safety
clearances when installing below a worktop.
To ventilate the appliance, the intermediate floor must
have a ventilation cut-out.
The worktop must be secured to the fitted unit.
21.5 Installing below a hob
If the appliance is installed below a hob, the following
minimum dimensions must be adhered to (including
substructure, if applicable).
The required minimum worktop thickness
on the required minimum clearance
Hob type
raised in
mm
Induction hob
48
is based
⁠ .
flush in
in
mm
mm