Clearing The Juice Outlet Of The Juice Collector; Solving Problems - Gastroback ADVANCED PRO S Operating Instructions Manual

Citrus juicer
Hide thumbs Also See for ADVANCED PRO S:
Table of Contents

Advertisement

5. Ensure that the juice will flow through the juice outlet, when opening the drip-stop
feature by pushing down the juice spout. If the juice outlet is clogged, remove
the obstacle (see below: 'Clearing the Juice Outlet of the Juice Collector').
6. After removing the juicing cone, always ensure that the interior of the juicing cone
is completely clean and dry, before re-assembling the juicing cone. Otherwise,
liquids may run onto the motor base or the juicing cone sticks to the drive shaft.
7. Re-assemble the juicing system completely and correctly (see: 'Assembling the
Appliance'). Thereafter, you may continue juicing.

CLEARING THE JUICE OUTLET OF THE JUICE COLLECTOR

CAUTION
– At the latest, when the juice fills the juice collector up to the strai-
ner of the filter basket, the juice collector must be emptied. Do not let the juice level
rise up to the rim of the filter basket! Otherwise the juice could splash during juicing
and run or drip on or under the motor base, causing risk of electric shock and fire.
1. If the juice spout is folded up to the closed position, place a suitable large juice
vessel (minimum volume: 1/2 litres) under the juice spout. Then push the juice
spout down for opening the juice outlet, letting the juice flow out. If the juice
does not flow, fold the juice spout up to the closed position again. Remove the
juice vessel.
2. Ensure that the appliance is unplugged. Then remove the fruit dome from the
press arm (see: 'Disassembling the Appliance').
CAUTION
– If the juice reached the rim of the filter basket already, you need
to remove the juicing cone and filter basket, before removing the juice collector.
Otherwise the juice could drip or run onto the motor base. If required, use a spoon
or little ladle for taking out some juice, before removing the juice collector from the
appliance. Handle the juice collector with special care, when pulling the juice
collector out of the top plate of the motor base, to avoid spilling the juice.
3. If the juice reached the rim of the filter basket, remove the juicing cone and filter
basket separately. Otherwise you may remove the juice collector, filter basket,
and juicing cone together (see: 'Disassembling the Appliance').
4. If required, spoon out some juice and with the juice level lowered sufficiently,
carefully pull out the juice collector (see: 'Disassembling the Appliance').
CAUTION
– Do not poke in the juice outlet. Rinse any residues of pulp that
may have accumulated within the juice outlet via a jet of water.
EN
20
5. Completely empty the juice collector over a large bowl. Fold the juice spout
down to the open position. Thereafter, you can rinse the juice outlet via a jet of
running tap water.
6. Ensure that the juice outlet is clear again and the juices will flow freely. Rinse the
filter basket and juicing cone. Thereafter, thoroughly dry the exterior of the juice
collector and the interior of the juicing cone. If required, clean the drive shaft
too for avoiding that the juicing cone sticks to the drive shaft.
7. Re-assemble the juicing system (see: 'Assembling the Appliance'). Thereafter you
may continue juicing as usual.

SOLVING PROBLEMS

If any problems occur during operation, you will find solutions in this section.
– Before starting your troubleshooting and making any mani-
WARNING
pulations at the appliance, always unplug the appliance!
Problem
Possible Reasons
Emergency stop required?
You find it difficulty to
The juice collector is not in
insert the juice collector
correct orientation.
into the top plate of the
motor base.
The juicing cone does not
A small gap of approx.
completely slip down on
1/2 cm of free space
the drive shaft.
must be left.
There are some residues
of juice and/or pulp sti-
cking to the interior of the
juicing cone.
The fruit dome cannot be
The appliance is not
lowered correctly onto the
assembled correctly.
juicing cone.
The Easy Solution
Unplug the appliance.
The juice spout must be inserted in the groove of the top
plate. Turn the juice collector accordingly.
Hold the juice collector somewhat inclined for inserting
the juice collector at the front side (juice spout) first.
Then, without violence press the juice collector down all
over, until it settles without any gaps on the rim of the
top plate. If required, turn the juice collector a little to
and fro to make it settle correctly within the top plate.
There must be a small gap between the strainer of the
filter basket and the juicing cone for allowing the juicing
cone to turn during operation. This is correct.
Clean the interior of the juicing cone and the drive shaft. Do
not attempt to press the juicing cone down with violence.
Ensure that the juice collector is engaged correctly at the
top plate of the motor base. Ensure that only one sin-
gle filter basket is inserted in the juice collector.
EN