Dual Valve Installation/Removal
6.11
Remove the upper table.
Dual valve screws are removed from the body.
Dual valve hose clamp is pulled back on the hose.
Hose is removed from the end on the valve.
At the back of the body, the tab fixing the valve to the body is pushed inside with
a screwdriver and the valve is turned left.
Picture 6.87 Valve Installation / Removal
Picture 6.88 Valve Installation / Removal
Picture 6.89 Valve Installation / Removal
Sensitivity: Public
BLG15 C7S SERVICE MANUAL
Remove the cable sockets on
the valve.
Remove the clamp using pliers
to release the condenser hose
from the valve as shown in
Picture 6.88. Picture 6.89.