BLG15 C7S SERVICE MANUAL

Step 2: Bluetooth Test

Description:
This step is not performed in service mode.
Condition to pass to the next step:
Timeout: If "Start/Pause" button is not pressed within 2*3 = 6 minutes, it goes into
"OFF" mode.
Switching to next step:
It automatically proceeds to the other step.
For independent controls:
Knob cannot be turned in this stage.

Step 3: Software version check

Description:
Software version can be displayed in this step. "1", which is the step number is
displayed at the beginning of step. When knob is moved to position 2, Software
version will be displayed.
Warnings to be displayed on the 7S:
Refer to the knob position and information table.
Condition to pass to the next step:
Timeout: If "Start/Pause" button is not pressed within 2*3 = 6 minutes, it goes into
"OFF" mode.
Switching to next step:
Press the "Start/Pause" button.

Step 4: LED and LCD segment check

Description:
All "LEDs" on the panel, all icons and points on LCD will be turned on and off (Open
Circuit / Short Circuit check)
When this step is completed, all LEDs and LCD will be turned off.
Warnings to be displayed on the 7S:
Refer to the knob position and information table
Condition to pass to the next step:
Timeout: If "Start/Pause" button is not pressed within 2*3 = 6 minutes, it goes into
"OFF" mode.