1-2 Indoor fan control
This control uses the thermistor for the indoor heat
exchanger to control cold air blowing prevention, the
indoor fan, and overheating prevention.
(˚C)
H
53
G
50
F
47
E
44
D
38
C
32
B
26
A
(1) Control for indoor freezing prevention
If the temperature of the indoor heat exchanger
stays below approximately 0°C for four minutes
during cooling or dry, this control stops the
compressor. Over 2˚C the compressor will run
again.
(2) Control for cold air blowing prevention
When heating begins, this control stops the indoor
fan until the temperature of the indoor heat
exchanger reaches 26°C. It also stops the fan if
the temperature goes below 23°C during
operation.
(3) Indoor fan and operating frequency
The indoor fan has 12 speeds, and changing is
done in four stages, "Auto", "High", "Med", and
"Low". The relations between the indoor fan
speed, air quantity setting, operating frequency,
and indoor heat exchanger are shown in the
following charts.
COOLING
Fan speed : High / Med / Low
11
10
9
8
7
6
5
4
3
2
1
OFF
OFF
1
2
3
Frequency cord
Fan speed : Automatic
11
10
9
8
7
6
5
4
3
2
1
OFF
OFF
1
2
3
Frequency cord
Differential
3˚C
Cold air blowing
prevention line
High
Med
Low
4
5
6
7
8
9
4
5
6
7
8
9
HEATING
Fan speed : High / Med / Low
12
11
10
9
8
7
6
5
4
3
2
1
OFF
OFF
1
2
3
Frequency cord
Fan speed : Automatic
12
11
10
9
8
7
6
5
4
3
2
1
OFF
OFF
1
2
3
Frequency cord
12
11
10
9
8
7
6
5
4
3
2
i zone
1
0
1
Operating frequency code
12
11
10
9
8
7
6
5
4
3
2
1
Operating frequency code
15
High
D - H
Med
D - H
Low
D - H
C
B
A
4
5
6
7
8
9
A
B
C
G, H
F
E
D
C
B
A
4
5
6
7
8
9
A
B
C
Dry
e, f zone
g zone
h zone
2
3
4
Circulation
High
Med
Low
0
AH-X079E/X099E
AY-X079E/X099E