AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
FOR OUTDOOR UNIT [AU-X08CR/X010CR/X13CR, AE-X08CR/X010CR/X13CR]
CAUTION : DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY
1. Loose a screw fixing the side cover.
2. Loose the unit to unit cord.
3. Loose a screw fixing the cord clamp.
Right side view
4. Loose 4 screws fixing the top panel.
Left side view
38
Right side view
Front view
5. Loose 6 screws fixing the front panel.
6. Cut 4 nylon bands.
7. Disconnect following connectors and each wire.
Choke coil(two terminal)
Fan motor
Thermistor
Reverse valve (AE-X08CR/10CR/13CR)
SERVICING
Left side view