Sharp AH-X08CR Service Manual page 29

Hide thumbs Also See for AH-X08CR:
Table of Contents

Advertisement

FOR INDOOR UNIT [AY-X08BCR/X10CR/X13CR AND AH-X08CR/X10CR/X13CR]
CAUTION : DISCONNECT THE UNIT FROM THE POWER SUPPLY BEFORE ANY
1. Open the opne panel, and remove 2 air filters.
2. Remove 4 screws fixing the front panel.
3. Remove the screw fixing the cord clamp.
Note: During reassembly, install the holder after
installing the front panel. This will make it
easier to assemble the front panel.
4. Close the open panel. Pushing the nail of the front
panel.
DISASSEMBLING PROCEDURE
33
5. Pull the front panel up.
6. Remove the unit-to-unit wiring from the terminal
board.
7. Remove a screw fixing the control box cover, and
remove it.
8. Remove a screw fixing the ground wire.
Note: During reassembly, take care for the
direction of the lead wire.
AH/AY-X08CR
AH/AY-X10CR
AH/AY-X13CR
SERVICING

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents