Environmental Specifications; Rtc360/Rtc360 Lt - Leica RTC360 User Manual

Hide thumbs Also See for RTC360:
Table of Contents

Advertisement

Power supply port
6.5
6.5.1
Environmental spe-
cifications RTC360/
RTC360 LT
48
Lemo1, 5 pin female
1
2
5
3
4
010744_001
Pin
Name
1
PWR_IN
2
NC
3
GND
4
GND
5
PWR_IN

Environmental Specifications

RTC360/RTC360 LT

Temperature range:
Type
RTC360/RTC360 LT
Protection against water, dust and sand:
Type
RTC360/RTC360 LT
Humidity:
Type
RTC360/RTC360 LT
Lighting:
Type
RTC360/RTC360 LT
Function
Power-In, 24 V
Do not connect
Ground
Ground
Power-In, 24 V
Operating temperature
[°C]
−5 to +40
Protection
IP54 (IEC 60529), upright ±15°/
upside down ±15°
Dust protected
Protection against splashing water from any dir-
ection
IP51 (IEC60529), in any other position
Dust protected
Protection against dripping water
Protection
Max 95% non-condensing
Conditions
Fully operational from bright sunlight to complete
darkness.
Storage temperature
[°C]
−40 to +70
Technical Data