Electric Characteristics - Haier AB072MRERA Service Manual

Table of Contents

Advertisement

19.6 Electric characteristics

Model
Phase FQY Voltage Volt range MCA
AF052MAERA
1
AF072MAERA
1
AF092MAERA
1
AF122MAERA
1
AF182MAERA
1
Symbols:
MCA: Min. circuit amps (A)
MFA: Max. fuse amps of circuit breaker
Output: Fan motor rated output (w)
FLA: Full load amps (A)
Note:
1. Voltage range
The units are applicable for the electrical systems where voltage supplied to unit is in the range.
2. Maximum allowable voltage unbalance between phases is 2%.
3. MCA=1.25*FLA MFA≤4*FLA
4. Power supply uses the circuit breaker.
Units
50/60
220
198~242
50/60
220
198~242
50/60
220
198~242
50/60
220
198~242
50/60
220
198~242
Power supply
Indoor fan motor
MFA Output (W)
0.28
0.88
20/11
0.28
0.88
20/11
0.28
0.88
20/11
0.28
0.88
20/11
0.28
0.88
20/11
485
Power input (w)
FLA
Cooling
Heating
0.22
100
100
0.22
100
100
0.22
100
100
0.22
100
100
0.22
100
100

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents