Haier AB092ACBHA Operation And Installation Manual

Cassette air conditioner
Hide thumbs Also See for AB092ACBHA:

Advertisement

Quick Links

CASSETTE AIR CONDITIONER
Operation & Installation
Manual
No.0010572402
B
Please read this operation manual before using the air conditioner.
Please keep this manual carefully and safely.
AB092ACBHA
AU092AABHA
(HBU-09HA03/R1(B))
AB122ACBHA
AU122AABHA
(HBU-12HA03/R1(B))

Advertisement

Table of Contents
loading

Summary of Contents for Haier AB092ACBHA

  • Page 1 CASSETTE AIR CONDITIONER Operation & Installation Manual No.0010572402 Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely. AB092ACBHA AU092AABHA (HBU-09HA03/R1(B)) AB122ACBHA AU122AABHA (HBU-12HA03/R1(B))
  • Page 2: Table Of Contents

    Contents Cautions ... Main points of Operation ... Name of Each part ... Safety Cautions ... Maintenance ... Trouble shooting ... When trouble happens ... Customer Need-to-know ... Installation Tools ... Installation Procedures ... Check and Test Run ... Malfunction Judgement... 9-11 15-22...
  • Page 3: Cautions

    Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier. Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
  • Page 4: Cautions

    Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner.
  • Page 5: Main Points Of Operation

    There is a telecommunication interface for remote control on the control panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be computerized and controlled from a far- away place.
  • Page 6 2 timer,the power failure compensation mode will be cancelled. Note: When a power failure suddenly occurs during the air conditioner si working after the power after the power failure compensationis set,if the air conditioner will not be used for a long time, please cut off the power supply to prevent its operation from being res- umed after the power is supplied again, or press the ì...
  • Page 7: Name Of Each Part

    Name of Each Part Indoor unit outdoor unit Air inlet Air outlet Swing louver (Air flow direction can be adjusted by using the SWING button on the remote controller) Electrical Components Case Air Inlet Grille Air Filter (Inside of the Inlet Grille) Connecting piping and electrical wiring Drain hose...
  • Page 8: Safety Cautions

    Safety Cautions Carefully read the following information in order to operate the air conditioner correctly. Below are listed four kinds of Safety Cautions and Suggestions: WARNING: Incorrect operations may result in severe consequences of death or serious injures. CAUTION : Incorrect operations may result in injures or machine damages;...
  • Page 9 Use discharge pipe correctly to ensure efficient discharge. In correct pipe usage may cause water leaking. Air conditioner canít be be installed in the environment with inflammable gases. The inflammable gases near to air conditioner may cause fire hazard. Installed electrical-leaking circuit breaker.
  • Page 10: Maintenance

    Maintenance Clean the unit Turn off the power supply switch Do not touch with wet hand. Do not use hot water or volatile liquid The 4 fixed bolts must be loosed as shown in the figure by arrow if they are bolts, the method is that: push the blots inward till to another edge.
  • Page 11: Trouble Shooting

    Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop. Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat.
  • Page 12 When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds ì Bi- Bi-î or ìGodo-Godoî. It is the flowing sound of the refrigerant , not a malfunction.
  • Page 13: Trouble Shooting

    Water or vapor generated from the outdoor unit during heating. During heating,indoor fan is still running even unit is stopped. Please check the following things about your air conditioner before making a service call. Is the power supply switch on ? Power cut? Power supply switch is not in ON position.
  • Page 14: When Trouble Happens

    Insufficient cooling Sunlight direct into the room ? When the air conditioner does not operate properly after you have checked the above-mentioned items or when following phenomenon is observed,stop the operation of the air conditioner and contact your sales dealer.
  • Page 15: Customer Need-To-Know

    Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual for future reference when maintenance and changing installation place.
  • Page 16: Installation Tools

    Installation Tools Installation tools The installation tools listed in the following sheet can be used as required. 1. Screw driver 2. Hacksaw 3. Drill with a diameter of 60mm 4. Inner hexagon spanner,shifting spanner 5. Spanner (14, 17, 19,24,27mm) 6. Pipe cutter 7.
  • Page 17: Installation Procedures

    Installation Procedures Installation of Outdoor Unit Selection of installation place Place strong enough to support unit weight, and will not cause vibration and noise. Place where discharged wind and noise do not cause nuisance to the neighbors, and is sufficiently ventilated.
  • Page 18: Selection Of Installation Place

    Installation Procedudres 1.Selection of Installation Place (1) Place above the ceiling where have enough space to arrange the unit. (2) Place where the drainage pipe can be arranged well. (3) Place where inlet and outlet air of indoor and outdoor unit will not be blocked. (4) Do not expose the unit to the place with heavy oil or moisture (e.g.kitchen and workshop).
  • Page 19: Installation Of Indoor Unit

    Installation Procedures (3) Install a suspending bolt To support the unit weight ,anchor bolt should be used in the case of already exists ceiling. Fow new ceiling, use flush-in type bolt, built-in type bolt or parts pretared in the field. Before going on installing, adjust space to ceiling.
  • Page 20: Installation Of Water Drainage Pipe

    Installation Procedures 3.Installation of water drainage pipe (1) Install water drainage pipe Pipe diameter shall be equal or larger than that of connecting pipe (Pipe of polythene; size: 25mm; O.D.: 32mm ) Drainpipe should be short, with a downward slope at least 1/100 to prevent air bag from forming. If downward slope of drainpipe cannot be made,lifting pipe shall be installed.
  • Page 21 Installation Procedures 4. Installation of Ornament Panel Install ornament panel on indoor unit (1) Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and check that the dimension of the ceiling opening is correct. Take off the lever gauge before install the ornament panel.
  • Page 22: Piping Connection

    Installation Procedures Piping Connection Flare connection Indoor Unit (1) Dimension of connecting pipe Gas pipe Liquid pipe Fit the nut on and fasten (2) The maximum length and drop height of connecting pipe The maximum length is 10m The maximum drop height is 5m. To ensure the efficiency ,Pipes shall be as short as possible.
  • Page 23 After attaching the each caps, check the gas leakage around the caps. CAUTION: If the refrigerant of the air conditioner leaks, it is necessary to make all the refrigerant out, then charge the liquid refrigerant into air conditioner according to the amount marked on the name plate.
  • Page 24: Installation Procedures

    Be sure to use rubber-damping cushion to reduce unit vibration. 2.Installation of drain elbow Installation of drain elbow.(Only for heat pump type air conditioner, no drain elbow for single cooling type).If use drain elbow,please install as shown in the figure.
  • Page 25: Check And Test Run

    Other Instructions 1.Configuration of power supply Air conditioner must use special power supply system (above 20A), and qualified electrician makes wiring and fixing according to wiring regulations specified in national standard. In socket, exactly distinguish earth wire with neutral wire and it is wrong to connect them together.
  • Page 26: Malfunction Judgement

    Malfunction Judgement Malfunction judgement Malfunction Malfunction cause code Power supply led Malfunction of the room temp.sensor flash 1 time Malfunction of the Power supply led piping temp.sensor flash 2 time Malfunction of the Power supply led overload heat flash 4 time Malfunction of the Power supply led overload cool...

Table of Contents