Switching on gas operation
Never operate the water heater without water in it!
If the wall cowl is positioned close to an opening
window (or hatch) – in particular directly under it –
the window must remain closed when the water heater is in
use (see warning plate).
Removing the cowl cover
– Grab the handle of the cowl cover.
– Press the palm against the lid (Fig.3a - 1) while pulling the
lid off the cowl (Fig.3a - 2).
1
Fig. 3a
Select water heater mode
– Use the control panel to select the water heater mode.
a
Fig. 3b
a = Red indicator lamp "Fault"
b = Water heater "On" 60 °C
c = Water heater "Off"
d = Water heater "On" 70 °C
If there is air in the gas supply line, it may take up to a minute
before the gas is available for combustion. If the appliance
switches to "Fault" during this time, switch off the appliance
– wait 10 minutes – and switch on again!
When using the vehicle switches
Refer to operating instructions of the vehicle manufacturer or
see switch labels.
Switching off gas operation
– Switch off the water heater to position (Fig. 3b - c).
If the water heater is not to be used for a longer period,
mount cowl cover (non-observance of this point can lead to
the function of the appliance being impaired through water,
dirt or insects), close stop cock valve in the gas supply line
and close the gas cylinder.
2
Fig. 4
2
UltraRapid
b
60°
c
d
70°
1
Before setting off on any journey, fit cowl cap with the Tru-
ma UltraRapid switched off. Please ensure that it is secure
and has locked into place (risk of accident). Defective cowl caps
must not be used. Drain the water heater if there is a risk of
frost! Warranty claims will not be accepted if this is ignored.
Red indicator lamp "Fault"
The red indictor lamp (a) lights up if there is a fault. For pos-
sible causes please refer to „Fault finding" on page 6. To
unlock, switch off the appliance, wait 10 minutes, and switch
on again.
Electrical operation 230 V
– option –
230 V
/ 240 V
1300 W / 1415 W (5.7 A / 5.9 A)
The Truma UltraRapid must not be operated with a
time switch.
Never operate the Truma UltraRapid without water in
it!
The water temperature cannot be selected, automatic
temperature limitation at approx. 70 °C! For a faster
heating up period the appliance can be simultaneously oper-
ated with gas and electrical power.
Maintenance
Do not modify this appliance.
Servicing should be carried out only by authorised
personnel.
Only original Truma parts may be used for maintenance and
repair work!
Please contact Service Australia for service and repairs.
Materials in the device which come into contact with wa-
ter are suitable for use with drinking water (see manufac-
turer declaration: www.truma.com – Manufacturer Declaration).
Decalcification
The Truma UltraRapid must be descaled on a regular basis (at
least twice a year).
We recommend the use of suitable normal commercial products
for the cleaning, disinfection and care of the Truma UltraRapid.
Products containing chlorine are unsuitable.
– In order to avoid the colonization of micro-organisms, heat
up the Truma UltraRapid to 70 °C at regular intervals.
– The drain valve (Fig. 2 - 3) and the P&T relief valve
(Fig. 2 - 4) are to be operated regularly to remove
lime deposits and to ensure that they are not blocked.
Frequency: every 6 month.
/ 240 V
5
Need help?
Do you have a question about the UltraRapid LPG and is the answer not in the manual?
Questions and answers